Showing 1-20 of 58 trials
NCT05850936
Currently, whether and when intraocular pressure (IOP) lowering medication should be used in progressive high myopia (HM) to control axial elongation is still a dilemma. Randomized trials are required to evaluate whether IOP lowering influences the growth of axial length in progressive HM eyes.
NCT07424417
This prospective randomized controlled trial aims to evaluate the effect of different upper extremity positions on intraocular pressure (IOP) in adult patients undergoing open inguinal hernia repair under spinal anesthesia. Participants will be randomly assigned to one of three arm positions: adduction alongside the body, 90° abduction, or arms crossed over the chest. IOP will be measured using a Tono-Pen AVIA tonometer at predefined intraoperative time points. Hemodynamic parameters including mean arterial pressure, heart rate, and oxygen saturation will also be recorded. The primary outcome is the change in intraocular pressure over time among the three groups. The findings of this study may provide clinically relevant data regarding the impact of upper extremity positioning on ocular physiology during spinal anesthesia.
NCT07152808
The primary objective of this clinical study was to show that tonometry values for TONOREF III, as the representative device of the NIDEK tonometer series, were comparable to the predicate device. The secondary objective was to demonstrate that the test device was as safe as the predicate device.
NCT04281017
Steep Trendelenburg positioning and insufflation of the abdominal cavity have shown to increase intra ocular pressure. Different anesthetic techniques can alter intra ocular pressure and a small pilot study showed decrease in Intraocular Pressure (IOP) in robotic case in steep Trendelenburg with IV anesthetics (TIVA). We want to quantify the degree of change in Intraocular Pressure (IOP) in female patients undergoing robotic procedures for cancer. We want to detect the difference in increase of pressure with total IV anesthesia versus conventional balanced anesthesia
NCT07073937
The goal of this study is to learn if combining minimally invasive glaucoma surgery (MIGS) procedures with different mechanisms of action increases the effectiveness of MIGS. The main question the study aims to answer is: Does combining viscodilation (a surgical technique, often used in glaucoma treatment, that involves using a high-viscosity, elastic gel to widen and open the Schlemm's canal, a main drainage channel in the eye) with the iTrack catheter, along with the Hydrus microstent, show better reduction in intraocular pressure than cataract surgery alone? Researchers will retrospectively review charts of patients who have open-angle glaucoma who have undergone combination Hydrus implantation and 360-degree iTrack canaloplasty with concomitant cataract surgery, who have at least 36 months of clinical follow-up data. Baseline demographic information and severity of glaucoma will be recorded, as will change from baseline yearly to three years in average optical coherence tomography (OCT) retina nerve fiber layer (RNFL) measurements and visual field (VF) pattern standard deviation. Safety outcomes and the percentage of eyes requiring secondary surgical intervention will be recorded at yearly time points.
NCT06275308
This study is to investigate the relationship between arterial carbon dioxide (CO2) concentration and vitreous pressure on the choroidal volume by integrated intraoperative OCT imaging under eye exams under anesthesia.
NCT07156630
The aim of this clinical study is to compare the agreement and precision of the intraocular pressure (IOP) results measured with the Quick Measure feature of iCare ST500 and iCare IC200 tonometers with results obtained with reference tonometers (Goldmann applanation tonometry and Tono-Vera tonometer). The data will be collected and evaluated in accordance with ISO 8612:2009 "Ophthalmic Instruments - Tonometers" (at least 120 eyes divided in three IOP groups with a minimum of 40 eyes per group, 95% of the paired differences between the reference tonometer and the test tonometer must fall within the tolerance of ±5 mmHg).
NCT06689696
The goal of this clinical trial is to learn if a new contact lens device can record patterns in eye pressure for 24 hours in adults with glaucoma and in healthy participants. The main questions it aims to answer are: * Is the contact lens device able to detect patterns in eye pressure that happens naturally between nighttime and daytime? * Are the contact lens recording patterns similar when repeated one week later? * What eye problems do participants have when wearing contact lens for up to 24 hours? Researchers will compare if the recordings detected by the contact lens over 24 hours are similar to the patterns measured by an eye pressure measuring instrument used in a doctor's office. Participants will * Wear contact lens in one eye for up to 24 hours * Take recordings in that eye with smartphone camera every 15 minutes when awake * For those participants who are able to stay overnight at a hotel for the trial, researchers will measure the eye pressure in the other eye every 1 to 2 hours when awake with an eye pressure measuring instrument.
NCT04698876
The SALUS project is developing a new form of care, the application of self-tonometry by the patient itself, and an accompanying electronic case file connecting clinics, doctor's offices and patients.
NCT04308941
The goal of this research is to determine the reproducibility of measurements of intraocular pressure (IOP) when a scleral lens is on the eye. The PROSE device (PD) is a specialized scleral lens that is filled with preservative-free saline and then applied to the eye in order to treat a variety of ocular conditions. The fit of the PROSE device is optimized to land gently on the conjunctival tissue overlying the sclera while completely vaulting the cornea and limbus without touch. Because the PROSE device vaults and therefore covers the cornea, measuring IOP during PROSE wear is challenging as traditional techniques rely on corneal contact (i.e. Goldmann tonometry, iCare, pneumatonometry, etc.). Measuring IOP before insertion and after removal of the PROSE device likely does not correspond to the true IOP when the PROSE device is actively on the eye. This is a prospective study of the reproducibility of three non-traditional means of IOP measurements: scleral tonopen, scleral pneumatonometry, and transpalpebral Diaton tonometer. Evaluating these means of measurements may be important for future studies investigating the effect of PROSE wear on intraocular pressure.
NCT05763056
Brief Summary: In this study, the investigators aimed to compare the effects of different types of endotracheal instruments (Machintosh laryngoscope, McGrath videoingoscope and C-Mac videoryngoscope) on intraocular pressure, optic nerve diameter and hemodynamic parameters.
NCT04962009
This is a pilot, open-label, multi-center clinical study. Each potential subject that has met all screening inclusion/exclusion criteria will undergo a six-week washout phase where they will discontinue the use of their topical hypotensive medication. After the six-week washout, each potential subject will return for a baseline visit. Investigators will verify that a potential subject has discontinued the use of their topical hypotensive medication(s) and all their prohibited systemic medications for the last 6 weeks. In addition, each subject will have discontinued the use of all other ocular drops, gels or ointments 24 hours prior to the visit (Visit 2) and continues to meet all screening and washout criteria. After completing the baseline examination, each potential subject that meet all baseline inclusion/exclusion for the treatment phase of the study will have his/her lower puncta of each eye inserted with a Travoprost Evolute®. Each study subject will be instructed to return to the investigator's office the next day, 7, 28, 60 and 90-days after the insertion of their plugs for follow-up examinations.
NCT04700189
The purpose of this study is to evaluate the safety and Intraocular pressure lowering effectiveness of the Streamline™ Surgical System.
NCT03624361
The study will evaluate the efficacy and safety of the MINIject glaucoma implant and Intraocular Pressure (IOP) lowering effects with or without glaucoma medications. The procedure will be a stand-alone surgery. Overall, the patient will be asked to perform several examinations up to 24 months after surgery.
NCT02138279
The primary objective of this clinical study is to collect clinical data to support FDA 510(k) submissions for the Topcon CT-800, CT-1, CT-1P and TRK-2P non-contact tonometers. The secondary objective is to evaluate any adverse events found during the clinical study.
NCT03439774
The study will assess the CT-800 and TRK-2P for conformity to ANSI Z80.10-2014 Ophthalmic Instruments - Tonometers, to the FDA Guidance for Industry and FDA Staff, Tonometer-Premarket Notification \[510(k)\] Submissions, and to the applicable Supplemental Information Sheet. This clinical device study will also assess the substantial equivalence of TRK-2P to a predicate device in regard to pachymetry.
NCT04360369
Determine if the Tono-Vera Tonometer accurately measures intraocular pressure (IOP). The hypothesis of this test is to confirm the Tono-Vera Tonometer is equivalent to the Goldmann Applanation Tonometer (within +/- 5.0 mmHg).
NCT05162989
The aim of this clinical study is to provide information about the variability of the intraocular pressure (IOP) self-measurements with the iCare HOME2 tonometer in comparison to the variability of the IOP measurements with the reference tonometer (iCare IC200), over a wide range of IOP values.
NCT03933254
Pneumoperitoneum created during laparoscopic surgeries has some effects on human physiology. Increased intraabdominal pressure results in increased intrathoracic pressure, and eventually may result in increased intracranial and intraocular pressures. In this study we aimed to identify intraocular and intracranial pressure changes during the perioperative period due to the pneumoperitoneum created for laparoscopic cholecystectomy surgeries. Intraocular pressure will be measured directly from the eye. Intracranial pressure will be estimated by measuring optic nerve sheath diameter changes ultrasonographically.
NCT04211792
Intraocular pressure measurement (IOP) is part of a routine eye examination. High and low eye pressure may be linked to certain eye conditions such as glaucoma. The current gold standard for IOP measurement is a technique called Goldmann Applanation Tonometry (GAT). GAT requires the use of a Goldmann applanation tonometer mounted on a slit lamp. Apart from GAT, there are many other devices that can be used to measure IOP, including the iCare tonometers. In this prospective study, investigators will be measuring participant's IOP with GAT, Icare PRO, and Icare ic200 tonometers to see if there is an agreement in IOP between the different devices. Investigator will also look if there is a concordance between different tonometers in low, moderate and high IOP range. Given the postural requirements for performing GAT, patients with higher body mass index (BMI) tend to have difficulties with proper positioning at the slit lamp that may lead to inaccurate GAT measurements. To this end, investigators will analyze the effect of BMI on IOP measurements with different devices. Additionally, comfort level of the patients with different tonometry devices will be recorded using a visual analog scale.