Loading clinical trials...
Loading clinical trials...
Comparison of the Effects of Intubation With a Machintosh Laryngoscope, McGrath Videolaryngoscope and C-Mac Videolaryngoscope on Intra-ocular Pressure, Optic Nerve Sheath Diameter and Haemodynamic Parameters
Brief Summary: In this study, the investigators aimed to compare the effects of different types of endotracheal instruments (Machintosh laryngoscope, McGrath videoingoscope and C-Mac videoryngoscope) on intraocular pressure, optic nerve diameter and hemodynamic parameters.
Detailed Description: Laryngoscopy and endotracheal intubation cause increased intracranial pressure due to hypoxia, hypercapnia, straining, or coughing. It may be an indirect result of increased arterial and venous pressure, as well as a direct effect of intubation. With the emergence of neuroimaging techniques and new diagnostic tools, various methods have been developed that can replace invasive methods, which are the gold standard in intraocular pressure measurement. However, invasive methods such as intraventricular and intraparenchymal catheter systems have some disadvantages and are associated with significant risks in terms of infection, bleeding, and time lost until follow-up. The intraorbital subarachnoid space surrounding the optic nerve shows the same pressure variation as the intracranial subarachnoid space, and any increase in intracranial pressure is also seen in the orbital subarachnoid space. With the increase in intracranial pressure, the optic nerve, optic nerve sheath diameter, and subarachnoid space enlarge. There are many studies reporting that optic nerve sheath diameter can be evaluated using ultrasonography. Although there is no clear cut-off value for optic nerve sheath diameter, previous studies have found that an optic nerve sheath diameter of 5.0 mm and above may indicate an increase in intracranial pressure. Previous studies have determined that the distribution of intraocular pressure in the adult population varies between 11 mmHg and 21 mmHg, and the mean intraocular pressure is 16.5 mmHg. It is well known that the sympathoadrenergic response caused by laryngoscopy and tracheal intubation significantly increases intraocular pressure (at least 10-20 mmHg). In addition, intravenous pressure and intraocular pressure increase due to cough, airway obstruction, succinylcholine use, hypoxia and hypercapnia during intubation. In this study, the investigators aimed to compare the effects of different types of endotracheal instruments (Machintosh laryngoscope, McGrath videoingoscope and C-Mac videoringoscope) on intraocular pressure, optic nerve sheath diameter and hemodynamic parameters.
Age
18 - 65 years
Sex
ALL
Healthy Volunteers
Yes
Inonu University Medical Faculty
Malatya, Turkey (Türkiye)
Start Date
September 1, 2023
Primary Completion Date
November 8, 2023
Completion Date
November 8, 2023
Last Updated
November 9, 2023
120
ACTUAL participants
McGrath videolaryngoscopy
PROCEDURE
C-MAC videolaryngoscopy
PROCEDURE
Direct laryngoscopy
DEVICE
Lead Sponsor
Inonu University
NCT06689696
NCT07424417
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions