Heidelberg Retina Tomograph (HRT) in Vivo Confocal Microscopy to Evaluate the Ocular Surface Disorders of Healthy and Diseased Individuals
In vivo confocal microscopy (IVCM) has been used in clinical settings for more than 25 years, and is noninvasive, rapid and easily repeatable technique to investigate ocular surface disorders. It enables morphological and quantitative analysis of ocular surface microstructure. \[1-3\] As the technology advances, new IVCM machine, Heidelberg Retinal Tomograph with Rostock Corneal Module (HRT-RCM), was developed. Hardware and software modifications and acquisition techniques continue to expand the applications of the HRT-RCM for quantitative in vivo corneal imaging at the cellular level. The new software can access the corneal nerve more accurate. Here the investigators proposed this Institutional Review Board (IRB) to collect healthy persons and cases of different systematic diseases as well as etiologies of ocular surface diseases.
Heidelberg Retina Tomograph (HRT) in vivo Confocal Microscopy to Evaluate the Ocular Surface Disorders of Healthy and Diseased Individuals The purpose of this study is to evaluate the cornea of healthy persons and cases of differ-ent systematic diseases as well as etiologies of ocular surface diseases. 1\. In vivo confocal microscopy (IVCM) Three main confocal systems have been developed for IVCM: 1. the Tandem Scanning Confocal Microscope (TSCM) \[4-6\] 2. the ConfoScan 4 (Nidek Technologies Srl, Padova, Italy) \[7-8\] 3. the Heidelberg Retinal Tomograph with Rostock Corneal Module (HRT-RCM, Heidelberg Engineering, Ges.m.b.H., Dossenheim, Germany \[9-10\] The HRT-RCM is a laser scanning confocal microscope, operating by scanning a 670 nm laser beam in a raster pattern over the field of view. The system uses a high numerical aper-ture 63x objective lens (0.9 NA), and produces images with high contrast and better axial resolution (7.6 µm) than other in vivo confocal systems (9 µm for the TSCM and 24 µm for the ConfoScan). The HRT-RCM provides new built-in software for 3D imaging of the corneal structure. Quantitative imaging of the subbasal nerve plexus could be performed by CCMetrics sys-tem, a custom software program developed at the University of Manchester. \[11-12\] The IVCM has the advantage of imaging through moderately opaque tissues (scarring or edema of the cornea) and also observes the dynamic process in the cornea, i.e. inflammatory reaction monitoring in infectious keratitis, wound healing after refractive surgery.\[13-14\] The use of IVCM in the scientific research has been expanding rapidly over the past years. It has also been implemented for the clinical diagnosis of different ocular surface conditions as well as screening tool for patients undergoing treatment. The following are indication of IVCM: 1. Normal central cornea (aging, contact lens wear-related changes) 2. Dry eye disease 3. Corneal ectatic disorders, dystrophies, degenerations 4. Iridocorneal endothelial syndrome (ICE) syndromes 5. Keratitis (microbial, fungal, parasitic, viral) 6. Post-surgical evaluation of the cornea (cataract surgery, Laser ASsisted In situ Keratomileusis-LASIK, Laser Epithelial Keratomileusis-LASEK, Photorefractive keratectomy, keratoplasty) 7. Corneal deposits (pseudoexfoliation syndrome, drug-induced ) 8. Systemic diseases (DM, Parkinson's disease, systemic lupus erythematosus, Rheumatoid arthritis, Alzheimer's disease and dementia) 9. Evaluation of the conjunctiva ( conjunctivitis, neoplasia ) 10. Limbal stem cell deficiency ( chemical or thermal injury, Stevens-Johnson syndrome ) Study procedures Before examination, each patient signs the written informed consent. The patients undergo HRT in vivo confocal microscopy. Theses exam will be repeated every 3-6 months according to the disease status. In vivo confocal microscopy is routinely used examination modality for ocular surface disorders. (1) In vivo confocal microscopy In vivo confocal microscopy was performed with the HRT in vivo confocal microscopy real-time confocal microscope (Heidelberg Engineering, Ges.m.b.H., Dossenheim, Germany) . Its auto-scan software provides the automatic alignment and recording. The results would be analyzed using CCMetrics system, a custom software program developed at the University of Manchester. Before examination, one drop of topical anesthetic solution (proparacaine 0.5%, Alcaine) was instilled onto the ocular surface. After proper preparation, one drop of Vidisic gel (Bausch \& Lomb, Ges.m.b.H., Berlin, Germany) was applied. The patients were instructed to gaze in the direction opposite to the region of measurement. The scanning was performed continuously from the superficial conjunctiva to the stromal layer
Age
20 - 40 years
Sex
ALL
Healthy Volunteers
Yes
National Taiwan University Hospital
Taipei, Zhongzheng Dist., Taiwan
Start Date
July 31, 2019
Primary Completion Date
June 1, 2020
Completion Date
June 1, 2020
Last Updated
July 24, 2019
400
ESTIMATED participants
Lead Sponsor
National Taiwan University Hospital
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT02417740