The objective is to conduct a prospective, sham controlled, double-blinded, interventional crossover trial to compare standard terminal cleaning plus PX-UV (intervention) with standard terminal cleaning plus sham PX-UV (control) with crossover at 12 months, following a 6-month washout period. Outcome measures include the rates of HAIs, as well as the recurrence of genetically identical clinical strains of HAIs among patients on study units. The study will be conducted in 2 hospitals covering 16 total hospital units at Detroit Medical Center. Our central hypothesis is that the addition of PX-UV to standard terminal cleaning will be associated with a significant reduction in the rate of HAIs, as well as a reduction in the recovery of genetically identical strains of MDROs. The impact of PX-UV disinfection on rates of HAIs on study units will be determined by comparing rates of HAIs on a) study units where PX-UV is added to standard terminal cleaning practices to b) units where a sham UV disinfection system is added to standard terminal cleaning; and by comparing rates of HAIs on the same medical ward during each of two 12-month phases of a crossover study (one phase when a PX-UV device is added and one when a sham device is added to standard terminal cleaning). The long-term goal of this project is to establish the efficacy of terminal cleaning plus PX-UV in reducing rates of HAIs due to the following multi-drug resistant organisms (MDROs): C. difficile, vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae and Escherichia coli producing extended-spectrum beta-lactamases (ESBLs), methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter baumannii. At the conclusion of the proposed project, novel data will be generated from this rigorously controlled study regarding the effectiveness of PX-UV in reducing HAIs in a representative, real-world healthcare setting.
In 2011, 721,800 healthcare-associated infections (HAIs) were reported in the United States. The hospital environment has been increasingly recognized as an important determinant of HAI acquisition and prevention of HAIs has become a top priority for the U.S. Department of Health and Human Services (HHS). Terminal cleaning of a patient room is recognized as a critically important process to help prevent HAIs and involves extensive cleaning and disinfection of the room after a patient has been discharged from the room and before the subsequent patient has been admitted to the room. Pulsed xenon ultraviolet light (PX-UV) has been shown to be effective in killing a variety of pathogens including endospores of Clostridium difficile. PX-UV works quickly - the entire cycle time for use in a hospital room is 15 minutes. To date, the clinical impact of adding PX-UV to terminal cleaning has not been demonstrated in clinical trials with sham controls or in a crossover design. The long-term goal of this project is to establish the efficacy of terminal cleaning plus PX-UV in reducing rates of HAIs due to the following multi-drug resistant organisms (MDROs): C. difficile, vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae and Escherichia coli producing extended-spectrum beta-lactamases (ESBLs), methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter baumannii. The objective of this application is to conduct a prospective, sham controlled, double-blinded, interventional crossover trial to compare standard terminal cleaning plus PX-UV (intervention) with standard terminal cleaning plus sham PX-UV (control) with crossover at 12 months, following a 6-month washout period. Outcome measures include the rates of HAIs, as well as the recurrence of genetically identical clinical strains of HAIs among patients on study units. The study will be conducted in 2 hospitals covering 16 total hospital units at Detroit Medical Center. Our central hypothesis is that the addition of PX-UV to standard terminal cleaning will be associated with a significant reduction in the rate of HAIs, as well as a reduction in the recovery of genetically identical strains of MDROs. The impact of PX-UV disinfection on rates of HAIs on study units will be determined by comparing rates of HAIs on a) study units where PX-UV is added to standard terminal cleaning practices to b) units where a sham UV disinfection system is added to standard terminal cleaning; and by comparing rates of HAIs on the same medical ward during each of two 12-month phases of a crossover study (one phase when a PX-UV device is added and one when a sham device is added to standard terminal cleaning). At the conclusion of the proposed project, novel data will be generated from this rigorously controlled study regarding the effectiveness of PX-UV in reducing HAIs in a representative, real-world healthcare setting.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
Detroit Medical Center
Detroit, Michigan, United States
Start Date
July 7, 2017
Primary Completion Date
January 31, 2020
Completion Date
April 15, 2020
Last Updated
March 14, 2022
25,732
ACTUAL participants
Pulsed xenon ultraviolet (PX-UV) Device
DEVICE
Sham Device
DEVICE
Lead Sponsor
University of Michigan
Collaborators
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions