Loading clinical trials...
Loading clinical trials...
Showing 1-20 of 394 trials
NCT05839990
The aim of the study is to analyze the efficacy of the surgical tretment in patients with ascending aortic aneurysm and dilatation. And to assess rate of negative clinical scenarios in non-oparated patients with ascending aortic dilatation
NCT06658730
An observational, prospective multi-regional post-market registry collecting mid- and long-term data to assess outcomes through ten years of follow-up for subjects treated with GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System as a part of routine clinical practice. This post-market registry for the GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System (CTAG w/AC) is intended to demonstrate that thoracic endovascular aortic repair (TEVAR) for lesions of the descending thoracic aorta continues to be a suitable treatment option for appropriately selected patients.
NCT07640334
The goal of this study is to evaluate the safety of integrating the Aortic Dissection Detection Risk Score (ADD-RS) and D-dimer testing for ruling out acute aortic syndrome (AAS) in the emergency department (ED). The main question it aims to answer: Can the combination of the ADD-RS \<2, and D dimer \<500ng/mL rule-out AAS in ED patients without CTA? The researchers will recruit patients suspected with AAS in the ED, and the patients will receive a ADD-RS score, a D-dimer testing after signing a written consent.
NCT07399392
Severe symptomatic aortic stenosis (AS) with a high gradient is associated with a poor prognosis if not treated with valve replacement. Transcatheter aortic valve implantation has been shown in large randomized trials to be a safe and effective treatment option for patients at low, intermediate, or high risk. Transfemoral access for heart valve replacement is by far the most commonly used approach, as it is relatively easy to control and has a low complication rate compared to other access routes. The TAVI procedure requires two arterial access points: one with a large lumen for the TAVI prosthesis via the femoral artery, and a smaller second one for a pigtail catheter that guides the TAVI prosthesis into the optimal position. This secondary access is most often via a second artery. Vascular complications are the most commonly observed complications in transfemoral TAVI and are associated with poorer procedural outcomes. Recent data suggest that secondary vascular access via the radial artery may contribute to a reduction in vascular complications after TAVI. In patients undergoing coronary angiography and/or percutaneous coronary intervention, radial access has become the preferred strategy due to its proven reduction in vascular complications compared to femoral access. The use of radial access is associated with a lower incidence of vascular complications compared to femoral access. Recent non-randomized data suggest that radial access may be a safer alternative to traditional femoral access as a secondary arterial access in transfemoral TAVI. However, non-randomized retrospective comparisons are subject to selection bias and underreporting of complications. Therefore, a prospective randomized trial is needed to evaluate the value of radial access for secondary arterial access in patients undergoing transfemoral TAVI.
NCT07480395
The registry population consists of patients presenting with complex aortic pathologies amenable to endovascular aortic repair that requires the incorporation of bridging stents to maintain visceral artery perfusion
NCT07193888
The Navitor Japan Study is designed to evaluate the safety and performance of the Navitor™ valve used in combination with the FlexNav™ delivery system in a contemporary, real-world setting.
NCT05927090
Type A aortic dissection (TAAD) is a potentially life-threatening pathology associated with significant risk of mortality and morbidity. In acute forms of type A aortic dissection (TAAD) mortality is 50% by 24 h and 50% of patients die before reaching a specialist center. Rapid diagnosis and subsequent prompt surgical repair remain the primary goal for these patients. In the last decade it has been observed that improvements in diagnostic techniques, initial management and increased clinical awareness have contributed to a substantial increase in the number of patients benefiting from a prompt diagnosis and undergoing surgery.However, survival after surgical repair has not yet reached optimal follow-ups and is burdened by high in-hospital mortality(16-18%)The main approach to acute type B non-complicated aortic dissection (TBAD) has always been to use medicines to control the patient's heart rate and blood pressure. However, recent findings suggest that a large number of patients treated for acute complicated (TBAAD) and non-complicated TBAD experience aortic complications, such as aneurysmal degeneration, at a later stage.
NCT06168370
The POPular ATLANTIS trial aims to investigate CT-guided antithrombotic therapy compared to lifelong single antiplatelet therapy after a transcatheter aortic valve implantation (TAVI) procedure. Only patients without an indication for anticoagulants will be included in this trial. Currently, lifelong single antiplatelet therapy (mostly aspirin) is considered the standard of care for these patients. However, this approach poses a bleeding risk with only a minimal reduction in thromboembolic events. After 3 months, a CT scan will be conducted to assess the presence of thrombosis on the newly implanted TAVI valve. Based on the results of a 4D CT scan, the decision will be made whether the patient should receive no anticoagulant or antithrombotic therapy with apixaban. CT-guided antithrombotic therapy holds the potential for a greater reduction in thromboembolic events without increasing the bleeding risk.
NCT04960280
The purpose of this study is to determine whether recording heart sounds with an acoustic stethoscope, combined with artificial intelligence (computer information), will show similar abnormalities to an echocardiogram or cardiac catheterization.
NCT00583817
The purpose of this study is to assess the role endovascular therapy to treat aortic disease involving the ascending aorta, the aortic arch, and the visceral segment of the aorta (or thoracoabdominal aorta)
NCT07510451
The standard procedure during general anesthesia is to monitor vital functions, including cardiovascular functions such as cardiac electrical activity, using continuous ECG recording, blood pressure measurement with a sphygmomanometer, heart rate measurement, and tissue oxygenation measurement with a pulse oximeter. These are non-invasive methods, which are often insufficient in the case of extensive procedures within the abdominal aorta. In such cases, the anesthesiologist additionally use direct blood pressure measurements and central venous pressure measurements. To perform these measurements, it is necessary to insert a cannula into an artery (usually the radial artery) and a catheter into the central veins (through the internal jugular or subclavian vein). Vascular cannulation is an invasive method and may be associated with complications such as vascular thrombosis, infection at the puncture site or catheter-related infections, pneumothorax, air embolism, cardiac arrhythmias, neuropathies, hematomas, and bleeding. At the same time, they allow for a more accurate assessment of cardiovascular function and the implementation of appropriate treatment, including the administration of large amounts of infusion fluids, vasoconstrictors, and cardiac support drugs. In the current study, the investigators will additionally use a special sensor and monitor to assess the heart's performance (cardiac output) and its response to the treatment used, optimizing and supporting the circulatory system. This monitoring requires the insertion of a catheter into a central vein and artery, which is necessary during vascular surgery procedures and does not involve any additional invasive procedures. In the postoperative period, the investigators will analyze the frequency of abnormalities in laboratory tests routinely collected after surgery and the function of the central nervous system by performing simple non-invasive cognitive function tests. The benefits of using the method of assessing the patient's response to surgery and anesthesia in presented study are related to increased safety for each patient and improved perioperative treatment for all patients undergoing surgery.
NCT07548099
This research study is being conducted to test how an imaging drug called 64Cu-DOTA-ECL1i can be used to image an abdominal aortic aneurysm. 64Cu-DOTA-ECL1i is a drug used with an imaging test called a PET/CT (Positron Emission Tomography/Computed Tomography). The aim is to collect data using a new imaging drug called 64Cu-DOTA-ECL1i that may be able to create images of inflammation in the aorta, which is thought to be important in how aneurysms grow and develop and to understand how consistent these scans are across time and what might affect the inflammation.
NCT04443023
The study performs head-to-head comparison of two TAVI-valves: Sapien and Myval.
NCT07197736
Heart disease is the leading cause of death in the United States, and echocardiography (or "echo") is the most common way doctors look at the heart. Echo is safe, painless, and can detect major heart problems, including weak heart pumping and valve disease. Valve disease, especially aortic stenosis (narrowing) and mitral regurgitation (leakage), is common in older adults but often goes undiagnosed. While echo is the main tool for finding valve problems, it takes time, requires expert training, and results can vary between readers. Recent advances in artificial intelligence (AI), especially deep learning (DL), have shown promise in automatically analyzing heart images. However, past research hasn't fully tackled key echo techniques-like color Doppler and spectral Doppler-that are crucial for measuring how blood moves through heart valves. AI tools also face challenges in being used in everyday medical practice because of workflow issues, lack of real-world testing, and concerns about how the algorithms make decisions. At Columbia University Irving Medical Center, researchers have built a large database of heart tests over the last six years and developed AI programs to analyze echocardiograms. The current study will test whether providing AI analysis to cardiologists in real time during echo reading can make the process faster and more consistent.
NCT07532733
Transcatheter aortic valve implantation (TAVI) is now the standard procedure for elderly patients with severe aortic stenosis. This patient group is characterised by increased frailty, multiple comorbidities and limited physiological reserve, exposing them to an increased risk of intraoperative complications. The majority of TAVI procedures are now performed under conscious sedation, in order to limit the risks associated with general anaesthesia and to promote a faster recovery. However, this strategy carries a risk of intraoperative respiratory events, notably bradypnoea, oxygen desaturation and airway obstruction, particularly in elderly patients with comorbidities. The anaesthetic strategy, and in particular the type of sedation used, is likely to influence intraoperative respiratory and haemodynamic tolerance. Traditionally used agents, such as propofol combined with opioids, can induce dose-dependent respiratory depression. Conversely, dexmedetomidine, an α2-adrenergic receptor agonist, has a distinct pharmacological profile, characterised by sedation with a theoretically limited respiratory impact. However, comparative data regarding the impact of different sedation strategies on intraoperative respiratory tolerance during TAVI remain limited, justifying the conduct of this study. Dexmedetomidine is a selective α2-adrenergic receptor agonist, used in anaesthesia and intensive care for its sedative and anxiolytic properties. It induces what is known as 'cooperative' sedation, characterised by the maintenance of relative alertness, the possibility of interacting with the patient and, above all, a limited impact on spontaneous breathing. Physiologically, dexmedetomidine differs from conventional sedatives, such as propofol and opioids, in causing less respiratory depression, making it a particularly attractive option for conscious sedation. This property is essential in elderly and comorbid patients, particularly during procedures such as TAVI, where maintaining spontaneous ventilation is a major concern. Several clinical studies, particularly in procedural sedation and interventional cardiology, suggest that the use of dexmedetomidine is associated with better respiratory tolerance, with a reduction in episodes of desaturation, bradypnoea and the need for airway interventions, compared with strategies based on propofol and opioids. However, data specific to the context of TAVI under conscious sedation remain limited, particularly regarding the prospective and standardised assessment of intraoperative respiratory events. This study therefore aims to address this knowledge gap by assessing the effect of dexmedetomidine, compared with standard sedation using propofol-remifentanil, on intraoperative respiratory tolerance in patients undergoing TAVI under conscious sedation.
NCT06969729
the comparison of physician-modified stent-graft created in 3D models versus custom-made devices in the treatment of complex abdominal aortic aneurysm
NCT07469371
Severe aortic stenosis (AS) is often accompanied by coronary artery disease (CAD). While coronary computed tomography angiography (CCTA) is routinely used before aortic valve replacement (AVR) to evaluate coronary anatomy, it lacks physiological assessment of myocardial ischemia. This prospective, single-center, randomized controlled trial aims to evaluate whether integrating functional assessment using CT-derived fractional flow reserve (CT-FFR) with CCTA can optimize revascularization decision-making and improve clinical outcomes. A total of 300 severe AS patients scheduled for transcatheter or surgical AVR will be randomly assigned to either the experimental group (revascularization decisions guided by both CCTA and CT-FFR) or the control group (decisions guided by CCTA alone). Participants will be followed up for 1 year to assess major adverse cardiovascular events and other clinical outcomes.
NCT04206228
Iron deficiency is a prevalent nutritional deficiency and a common cause of anemia. Although iron deficiency is traditionally linked to anemia, iron deficiency is prevalent even in the absence of anaemia and in itself limits function and survival. Iron deficiency is a common feature of various chronic diseases, and up to 50% of patients with heart failure have iron deficiency. Iron deficiency is more prevalent the more advanced the disease is and occurs more frequently in women. Iron deficiency comprises absolute iron deficiency (usually defined as ferritin \< 100 ng/ml) as well as functional iron deficiency, in which iron supply is inadequate to meet the demand for the production of red blood cells and other cellular functions despite normal or abundant body iron stores. Iron deficiency is associated with poor exercise capacity, lethargy and reduced quality of life. Results from our studies have shown that iron deficiency is prevalent in patients with aortic stenosis. Some of the symptoms associated with aortic stenosis, such as fatigue, reduced exercise capacity, dyspnoea and cognitive dysfunction, have traditionally been thought to be caused by the haemodynamic derangements precipitated by the valvular stenosis. However, similar symptoms can be brought about by iron deficiency, and the investigators hypothesize that intravenous iron supplement will improve exercise capacity, muscle strength, cognition, health-related quality of life and myocardial function in patients with severe aortic stenosis and iron deficiency. This is a phase 2, double blind, randomised, placebo-controlled trial. Participants will be randomised in a 1:1 fashion to receive a single intravenous dose of iron isomaltoside (50 patients) or matching placebo (50 patients). The study is designed to show superiority with regard to the primary endpoint in patients assigned to active treatment versus patients allocated to the placebo arm. The main goal is to evaluate the effect of a single dose of intravenous iron isomaltoside on exercise capacity after transcatheter aortic valve implantation in patients with severe aortic stenosis and iron deficiency. For this study, the investigators have defined as serum ferritin \< 100 µg/l or ferritin between 100 and 300 µg/l in combination with a transferrin saturation \< 20 %.
NCT07529275
fenCo is a European multicentre, prospective study to evaluate the use of the iCover covered stents as bridging stents for reno-visceral target vessel during fEVAR for the treatment of complex abdominal aortic aneurysms.
NCT07528144
The goal of this clinical trial is to learn whether an exoskeleton-supported radiation protection system can reduce radiation exposure and musculoskeletal strain in vascular surgeons during endovascular aortic repair procedures, compared with standard lead aprons. Researchers will compare procedures performed with exoskeleton-supported protection and procedures performed with standard lead aprons. Radiation exposure, physical strain, fatigue, and discomfort will be assessed during and after procedures.