Loading clinical trials...
Loading clinical trials...
Showing 1-8 of 8 trials
NCT07304427
This is a prospective, single-arm, multi-center, post-market registry study conducted in China. The purpose is to evaluate the safety and effectiveness of the AlwideTM Plus balloon catheter for pre-dilatation of the aortic valve during TAVR in the real-world setting.
NCT01586910
The purpose of the study is to investigate the safety and efficacy of transcatheter aortic valve implantation (TAVI) in patients with severe, symptomatic Aortic Stenosis (AS) at intermediate surgical risk by randomizing patients to either Surgical Aortic Valve Replacement (SAVR) or TAVI with the Medtronic CoreValve® System. Single Arm: The purpose of this trial is to evaluate the safety and effectiveness of transcatheter aortic valve implementation (TAVI) in patients with severe symptomatic Aortic Stenosis (AS) at intermediate surgical risk with TAVI. This is a non-randomized phase of the pivotal clinical trial.
NCT06136429
Trial Title: Prospective, multicenter, single-arm target value clinical trial to evaluate the safety and efficacy of a transcatheter aortic valve system in the treatment of patients with severe aortic stenosis Test device: Transcatheter aortic valve system. Pilot Phase: Clinical Validation of Class III Medical Devices. Study design: prospective, multicenter, single-group target value. Sample size: 120 cases. Intended Use: The Transcatheter Aortic Valve System is indicated for patients with a diagnosis of severe aortic stenosis by the Comprehensive Heart Team. Objective: This clinical trial is a prospective, multicenter, single-arm study to evaluate the safety and efficacy of the transcatheter aortic valve system in the treatment of patients with severe aortic stenosis. Primary endpoint: 12-month postoperative all-cause mortality All-cause deaths include cardiac death and non-cardiac death. Secondary Endpoints: 1. Device success rate 2. Procedural success rate 3. Delivery system performance 4. Retrieval system performance (e.g. using a recycling system) 5. Exchange system performance 6. Valvular function at Immediately postoperative, 7 days/at discharge, 30 days, 6 months, 12 months, 2-5 years follow-up: valve stenosis, regurgitation, valve function (e.g., opening area, pressure gradient), paravalvular leakage 7. Improvement in quality of life at 30 days, 6 months, 12 months postoperatively 8. Improvement in cardiac function at 7 days/at discharge, 30 days, 6 months, 12 months, 2-5 years postoperatively Experimental design: This trial is a prospective, multicenter, single-group clinical study with a target value to evaluate the Transcatheter Aortic Valve system Safety and efficacy in the treatment of patients with severe aortic stenosis with 12 months of All-cause mortality after transcatheter aortic valve implantation. The mortality rate was the primary study endpoint, and after statistical assumptions and sample size calculations, 120 patients were planned to be enrolled. Patients were clinically followed immediately after valve implantation, 7 days postoperatively/at discharge, 30 days, 6 months, 12 months, and 2-5 years postoperatively. In this trial, all relevant clinical data were collected, sorted out and statistically analyzed by an independent data management and statistics center and a clinical monitoring institution. All enrolled subjects underwent outpatient follow-up at 30 days, 6 months, and 12 months after surgery, and performed relevant imaging examinations (ultrasound, etc.) and laboratory tests and safety evaluations, and continuous follow-up and cardiac ultrasound examinations were performed annually at 2-5 years to observe the occurrence of adverse events to evaluate the long-term safety of the transcatheter aortic valve system. The safety and efficacy of the transcatheter aortic valve system were evaluated with the subject's 12-month postoperative all-cause mortality as the primary endpoint, and the immediate postoperative device success rate, procedural success, retrieval system performance, valve function, cardiac function improvement, quality of life improvement, all-cause mortality in different follow-up periods, major adverse cardiovascular and cerebrovascular events, myocardial infarction, stroke, hemorrhage, acute kidney injury, permanent pacemaker implantation, serious vascular complications, and other TAVR-related complications were taken as the secondary endpoints to assist in evaluating the safety and efficacy of the test product, and to provide a basis for the final official listing and domestic marketing.
NCT01240902
The purpose of the study is to evaluate the safety and efficacy of the Medtronic CoreValve® System in the treatment of symptomatic severe aortic stenosis in subjects who have a predicted high risk for aortic valve surgery and/or very high risk for aortic valve surgery.
NCT04206228
Iron deficiency is a prevalent nutritional deficiency and a common cause of anemia. Although iron deficiency is traditionally linked to anemia, iron deficiency is prevalent even in the absence of anaemia and in itself limits function and survival. Iron deficiency is a common feature of various chronic diseases, and up to 50% of patients with heart failure have iron deficiency. Iron deficiency is more prevalent the more advanced the disease is and occurs more frequently in women. Iron deficiency comprises absolute iron deficiency (usually defined as ferritin \< 100 ng/ml) as well as functional iron deficiency, in which iron supply is inadequate to meet the demand for the production of red blood cells and other cellular functions despite normal or abundant body iron stores. Iron deficiency is associated with poor exercise capacity, lethargy and reduced quality of life. Results from our studies have shown that iron deficiency is prevalent in patients with aortic stenosis. Some of the symptoms associated with aortic stenosis, such as fatigue, reduced exercise capacity, dyspnoea and cognitive dysfunction, have traditionally been thought to be caused by the haemodynamic derangements precipitated by the valvular stenosis. However, similar symptoms can be brought about by iron deficiency, and the investigators hypothesize that intravenous iron supplement will improve exercise capacity, muscle strength, cognition, health-related quality of life and myocardial function in patients with severe aortic stenosis and iron deficiency. This is a phase 2, double blind, randomised, placebo-controlled trial. Participants will be randomised in a 1:1 fashion to receive a single intravenous dose of iron isomaltoside (50 patients) or matching placebo (50 patients). The study is designed to show superiority with regard to the primary endpoint in patients assigned to active treatment versus patients allocated to the placebo arm. The main goal is to evaluate the effect of a single dose of intravenous iron isomaltoside on exercise capacity after transcatheter aortic valve implantation in patients with severe aortic stenosis and iron deficiency. For this study, the investigators have defined as serum ferritin \< 100 µg/l or ferritin between 100 and 300 µg/l in combination with a transferrin saturation \< 20 %.
NCT03788590
The purpose of this study is to demonstrate that transcatheter artificial aortic valve and transcatheter artificial heart values delivery system is associated with a reduction of all-cause mortality in severe aortic stenosis or insufficiency patients who are high risk or ineligible for aortic valve replacement.
NCT03280433
This translational study was designed to explore the association of the quantity and quality of epicardial adipose tissue (EAT) with coronary artery disease (CAD), left atrial remodeling and postoperative atrial fibrillation in a high cardiovascular disease-risk population. The investigators expect to identify new biochemical factors and biomarkers in the crosstalk between the epicardial adipocytes, coronary plaques and atrial cardiomyocytes that are involved in the pathogenesis of atherosclerosis and atrial fibrillation, respectively.
NCT02159794
The purpose of this study is to evaluate the safety and performance of the HLT System in patients with severe aortic stenosis who present at High Risk for aortic valve replacement surgery.