Loading clinical trials...
Loading clinical trials...
Showing 1-18 of 18 trials
NCT04716218
In patients with limited neck extension and mouth opening due to reasons including previous radiation therapy in the head and neck area or cervical spine pathology, tracheal intubation with direct laryngoscopy (DL) are challenging because of the difficulty in aligning the oral, pharyngeal, and laryngeal axes in order to visualize the cords. In contrast, video-laryngoscopes (VL) only require alignment of the pharyngeal and laryngeal axes, which lie along much more similar angles when compared with the oral axis. Thus, VL make tracheal intubation easier to accomplish in these patients. Good patient positioning also maximizes the chance of successful laryngoscopy and tracheal intubation. In difficult airway society 2015 guidelines, advantages of head-up positioning and ramping, which brings the patient's sternum onto the horizontal plane of the external auditory meatus (EAM), are highlighted. In the obese patient, the 'ramped' position should be used routinely because this improves the view during DL. This position is usually achieved by placing blankets or other devices under the patient's head and shoulders, but can also be achieved simply by configuring the operation room (OR) table into a back-up head elevated (BUHE) position. Significantly improved glottic views on DL have been reported with both obese and non-obese adult patients in BUHE position. However, the effect of this simple maneuver on laryngeal visualization with the VL in patients with limited neck extension and mouth opening has not been reported. The investigators hypothesized that BUHE position might improve laryngeal views and make intubation easier compared to the supine position with the VL in patients with simulated difficult airway (application of a cervical collar to limit mouth opening and neck movement).The investigator investigated primarily the improvement in visualization of the glottis and, secondarily, the ease of tracheal intubation after alignment of the EAM and sternal notch.
NCT03779984
This study was designed to compare the effectiveness of using a red-rubber catheter versus standard, direct insertion of a thermosoftened, lubricated nasal endotracheal tube into the naris to facilitate nasotracheal intubation in adults. This study will assess if the red-rubber catheter method leads to lower incidence and severity of epistaxis, faster time to intubation, and higher patient satisfaction compared to the current standard of care.
NCT04457453
Pulmonary aspiration during tracheal intubation for anesthesia can cause fatal respiratory complications. Takenaka's study of mannequins reported that the risk of airway contamination by reflux gastric contents could be minimized by applying a 15-degree Trendelenburg position and a Sellick position with neck extention. However, the clinical performance of tracheal intubation in this position has not been studied. Also, the difference between the effects of direct laryngoscope and video laryngoscope on tracheal intubation is not known yet. Therefore, this study aims to compare the intubation time among intubation through direct laryngoscope and video laryngoscope in the Sellick and Trendelenburg position, and intubation in the conventional sniffing position.
NCT03340207
Pneumaglide is a device designed to facilitate intubation. Patients who are undergoing a surgical procedure under general anesthesia and will require placement of endotracheal tube will be screened and upon fulfilling the inclusion criteria will be randomized to PneumaGlide group or non-PneumaGlide group. After induction of anesthesia PneumaGlide device will placed in the mouth of the Pneumaglide assigned subject. The time for intubation will be measured from the time that the laryngoscope is inserted into the mouth until the trachea is successfully intubated and compared between the groups. Oxygen saturation drop below 90% and also gastric secretion spillage will be compared between two groups as well.
NCT04174833
This study aims to evaluate the clinical performance, quality of larynx visualization and difficulty of videolaryngoscopic intubation in patients with a reduced mouth opening (1.0 to 3.0 cm) utilizing the latest generation of GlideScopeTM Spectrum low profile laryngoscopy system.
NCT03341507
This study evaluates the efficiency of the rigid tube for laryngoscopy for tracheal intubation in patients with presumed difficult airway and compare the classical laryngoscopy and this method in matter of glottis visualisation and tracheal intubation.
NCT03889847
One lung ventilation (OLV) is required during thoracic procedure such as lung and esophagus surgery, and carried out by double lumen tube(DLT). Direct insertion of DLT over a fibreoptic bronchoscope (FOB) is considered more difficult and traumatic than that of a single-lumen tube. Recently, One recent simulation study demonstrated that a soft silicone DLT with a flexible, wire-reinforced bronchial tip (Fuji-Phycon tube) may shorten the time to intubation via tube exchange when compared with less compliant, polyvinyochloride(PVC) DLTs such as the Shilly or Rusch DLT. HumanBroncho® (Insung Medical, Seoul, Korea) is a new silicone DLT with a soft, flexible, non-bevelled, wire-reinforced tip. The oval shape, obtuse angle, and short lateral internal diameter of the bronchial lumen and its flexibility may allow for advancement to the trachea over the FOB easier than the Shilly tube. In the present study, The investigators aimed to test the hypothesis that the silicone DLT would be easier than PVC DLT with regard to railroading grade over an FOB. Investigators further aimed to compare the intubation time over the FOB between the silicone DLT and PVC DLT.
NCT04459481
Video intubating stylet can be safely and effectively used for nasotracheal intubation, but the optimal bending angle is still unknown. In this study, the optimal bending angle will be determined by comparing the intubation time and success rate of nasotracheal intubation with video intubating stylet at two different bending angles.
NCT04438772
Check the condition of intubation with LPEC compared with a sham procedure in the general anesthesia
NCT04101734
The purpose of this study is to assess the usefulness of the Thyromental Height Test in prediction of difficult intubation and the utility of double lumen video endotracheal tubes in patients scheduled for elective thoracic procedures.
NCT03645174
In difficult airway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option. Aintree catheter is a device to help change LMA to endotracheal tube, but it needs complex and multiple process. Long endotracheal tube can solve this problem of Aintree catheter. The purpose of this study is proving the efficacy of long endotracheal tube compared to Aintree cathter in fiberoptic-guided intubation through LMA.
NCT03576352
Study participants will be shown an illustrated training video demonstrating and explaining the RST. The video may be reviewed until the participant feels confident to perform procedure. The Rapid Sequence Tracheostomy (RST) consists of the following steps: 1. Orientational palpation and vertical midline skin incision followed by separation of the strap muscles 2. Exposure of the trachea and cricoid followed by anterior luxation of the trachea with a Backhaus towel clamp 3. Perform a vertical puncture with a tip scissors between the Cricoid and 1st tracheal ring followed by a vertical incision of no more than 2 rings in length. 4. An age adapted tracheal tube is inserted into the trachea and the lungs are ventilated. Teaching methodology: Prior to the hands-on training of eFONA, all participants shall watch a 2-minute training video of RST performed on rabbit cadaver following the steps outlined above. During video demonstration, no additional explanation or support will be provided. Once study participants express confidence to perform the skill, participants shall attempt to perform the RST 10 times. During the RST procedure no additional explanation or support will be provided. Study participants will be allowed to watch the video again between attempts, if needed. Each attempt will be video recorded and time recorded for rater analysis, as outlined above. Successful tracheotomy is defined as ventilation of the lungs by way of a standard self-inflating bag that is to be connected to the tracheal tube or visual confirmation of the tube being placed at least 2 cm inside the trachea (dissection of the rabbit cadaver performed by assistant).
NCT03578601
Intubation manoeuvres in patients undergoing thyroid surgery might be challenging for anesthesiologist. Thyroid gland enlargement (goiter) or tissue fibrosis (neoplasms) could alter the physiologic anatomy of upper airways and trachea, resulting in compression or dislocation. We want to evaluate the incidence and identify predictive parameters of difficult intubation in patients undergoing thyroid surgery.
NCT03567902
The aim of the study is to compare the effect of the C-MAC videolaryngoscope intubation technique vs. the conventional direct laryngoscope intubation technique on the cervical spine motion during intubation in patients with the simulated cervical immobilization.
NCT03424070
This study compares the distance from the operating table to the eye of the laryngoscopist while intubating the trachea with or without a shoulder roll. A photo of the glottic opening will compare the glottic views in both positions.
NCT03118622
Comparison of Intubation using Pentax (Pentas AWS, Pentax, Tokyo, Japan) and Macintoch in pediatric patients
NCT03173443
One lung ventilation (OLV) is required during thoracic procedures such as lung and esophagus surgery. three technique can be employed. (1) placement of a double-lumen bronchial tube (DLT); (2) use of a single-lumen tracheal tube (SLT) in conjunction with a bronchial blocker; (3) insertion of a conventional SLT into a main bronchus. Flexible fiberoptic intubation with SLT is well established technique for anticipated or unexpected difficult intubation. But, little is known about flexible fiberoptic intubation with DLT. The investigators compared insertion time over fiberoptic bronchoscope between SLT with bronchial blocker and DLT in patients undergoing thoracic surgery.
NCT03279172
The aim of the study was to compare intraocular pressure, intubation time, throat pain and hemodynamic variables using direct or videolaryngoscopy under general anesthesia requiring endotracheal intubation