Loading clinical trials...
Loading clinical trials...
Showing 1-6 of 6 trials
NCT06872905
The study will assess the safety and effectiveness of the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis ("VBX Device" or also referred to as "VBX Stent Graft") in a post approval setting and evaluate the quality of the use in covered endovascular reconstruction of the aortic bifurcation (CERAB) to treat Aortoiliac Occlusive Disease (AIOD).
NCT01793662
Patients with severe atherosclerotic occlusive disease can be operated on with an aortobifemoral bypass(ABFB)through a median laparotomy. Since 1993, this operation has also been performed laparoscopically. The laparoscopic ABFB operation claims to be minimally invasive as compared to the open ABFB. The cohort studies published so far have shown that although a longer operation time with the laparoscopic procedure as compared to the open surgery, the patients have a shorter hospital stay, lesser perioperative bleeding, fewer systemic complications, and earlier convalescence. However, no randomized control trial has yet been published to compare the two procedures. In the NLAST-study, which is a multicenter randomized control trial, the patients with TASC type D atherosclerotic lesions shall be randomized to either totally laparoscopic aortobifemoral bypass operation (LABFB)or an open ABFB operation.
NCT05811364
The objective of this prospective, multicenter, randomized, controlled clinical trial is to demonstrate the superiority of the VBX Device for primary patency when compared to bare metal stenting in complex iliac occlusive disease.
NCT06012123
The covered endovascular reconstruction of aortic bifurcation (CERAB) technique was described l in 2013 to reconstruct the aortic bifurcation in a more anatomical and physiological way. With the use of this technique, a covered stent is expanded 15 to 20 mm above the aortic bifurcation and this stent is proximally adapted to the aortic wall with a larger balloon, thereby creating a cone-shaped stent. Two iliac covered stents are then placed in the distal conic segment and simultaneously inflated, making a tight connection with the aortic stent, as if they were molded together, thus simulating a new bifurcation. This minimal invasive endovascular technique using covered stents, was developed in order to optimize endovascular mimicking the anatomical configuration of the aortic bifurcation and in an attempt to overcome the disadvantages of kissing stents influenced by geometric factors such as radial mismatch, protrusion mismatch and stent conformation. The use of BeGraft (balloon-expandalbe covered stent) and Solaris (self-expandable covered stent) fro this technique is revised.
NCT04148456
To evaluate the safety and efficacy of the CERAB technique as an alternative to surgical reconstruction for treatment of aorto-iliac occlusive disease.
NCT04458714
From July 2015 to July 2018, 64 patients with aortoiliac occlusive disease who were eligible for endovascular treatment and lacked contraindications to either iodine contrast or carbon dioxide (CO2) were randomized into the carbon dioxide CO2 group(32) or iodine contrast medium(ICM) group(32) were subjected to aortoiliac angioplasty. The primary outcome was the quality of image as the sole contrast agent used in interventions. The secondary outcomes were technical success rate and the safety of procedure.