Loading clinical trials...
Loading clinical trials...
Showing 1-20 of 150 trials
NCT07473102
A first-in-human evaluation of \[64Cu\]-RYM2 with PET/CT will be performed to: a) assess its safety, biodistribution, and radiation dosimetry in normal volunteers (WU) and; b) in AAA patients undergoing surgery (WU and Yale), evaluate radiotracer pharmacodynamics and correlate PET imaging characteristics (WU) with ex vivo tissue measurements (Yale).
NCT07480395
The registry population consists of patients presenting with complex aortic pathologies amenable to endovascular aortic repair that requires the incorporation of bridging stents to maintain visceral artery perfusion
NCT04246463
Multi-arm, multi-center, open label, prospective observational registry designed to obtain safety and performance data on the use of CE marked and custom Terumo Aortic endovascular grafts.
NCT04875429
The Zenith® Fenestrated+ Endovascular Graft Clinical Study will assess the safety and effectiveness of the Zenith® Fenestrated+ Endovascular Graft (ZFEN+) in combination with the BeGraft Balloon-Expandable FEVAR Bridging Stent Graft System (BeGraft) and Unibody2 for the treatment of patients with aortic aneurysms involving one or more of the major visceral arteries.
NCT07422129
Surgical indication in patients suffering from Ascending aorta aneurysm is currently based mainly on the maximum diameter of the aortic dilatation and on the yearly growth rate. Several clinical preoperative patients characteristics have been, potentially, correlated to impaired mechanical characteristics of aortic wall, and therefore to an increased risk of rupture and or dissection. On other hands, such suppositions have been never confirmed, as a full characterization of the mechanical behaviour of the ascending aortic tissue, especially in case of aneurysm, has not been fully clarified yet. Objective of this observational study is to better elucidate, using direct in vivo evaluation, the mechanical characteristics of the aortic wall in patients with ascending aorta diseases. Our study will have a further peculiar characteristic as we have the intention of compare such mechanical characteristics to those of patients, without known aortic diseases, undergoing heart transplantation. Potential correlation between, directly measured mechanical characteristics of the aortic wall, and preoperative parameters (anagraphic patients characteristics, clinical data and diagnostic tests) will be also investigated.
NCT05954793
The INNER-B-APAC post-market clinical follow-up study is undertaken to demonstrate the safety and clinical performance of the E-nside TAAA Multibranch Stent Graft System used in endovascular treatment of patients with thoracoabdominal aortic aneurysms.
NCT07078383
The Goal of this Clinical Study is to evaluate the safety and effectiveness of the Rapidlink device in the repair or replacement of the supra-aortic vessels during open surgical repair of aortic disease affecting the thoracic aorta. This study will collect information on patients who are already having surgery to repair their aorta and who will have Rapidlink device implanted into one or more of the aortic arch vessels. The first 32 subjects enrolled will undergo left subclavian artery repair or replacement, only, with the Rapidlink device. After the 32nd subject, enrollment will proceed to include subjects undergoing any supra-aortic vessel (i.e., left subclavian artery, left common carotid artery, and/or innominate artery) repair or replacement with the Rapidlink device in a planned surgery. After the 32nd subject is enrolled in the main group, up to 30 subjects will undergo supra-aortic vessel (i.e., left subclavian artery, left common carotid artery, and/or innominate artery) repair or replacement with the Rapidlink device in an emergency setting. Data will be collected before, during and after surgery including recovery at discharge, 30 days, 6 months, 1 and 2 years after the surgery.
NCT06218875
A prospective, observational post-market registry collecting outcomes through a 10-year post procedure follow-up for patients treated with the GORE® EXCLUDER® Conformable AAA Endoprosthesis (EXCC Device) or the GORE® EXCLUDER® Iliac Branch Endoprosthesis (IBE Device) as a part of routine clinical practice.
NCT04005976
The Montalcino Aortic Consortium (MAC) will provide the infrastructure to assemble large cohorts of patients with mutations in known heritable thoracic aortic disease (H-TAD) genes, define the phenotype associated with these genes, and determine genetic and environmental modifiers of H-TAD.
NCT02089607
The purpose of this study is to gather safety and effectiveness of the Zenith t-Branch and customized physician-specified stent-graft with a combination of fenestrations and/or branches to repair aortic aneurysm.
NCT00488696
This is a study to assess the safety and effectiveness of endovascular treatment of aortic aneurysms involving the proximal aortic arch. The investigational operation involves placing a stent-graft over the aortic aneurysm.
NCT07020611
The goal of this clinical trial is to evaluate the safety and feasibility of the Cygnum Aneurysm Sac Management Device in patients with abdominal aortic aneurysms treated with endovascular aneurysm repair (EVAR). The main questions it aims to answer are: 1. Is the Cygnum device safe when used adjunctively with standard EVAR endografts? 2. Does it effectively reduce or prevent type II endoleaks by managing the aneurysm sac? Participants will: 1. Undergo EVAR with adjunctive implantation of the Cygnum device 2. Have follow-up imaging (e.g., CT scans) and clinical assessments to evaluate device position and sac behavior over time
NCT05609539
The goal of this multicenter, observational cohort study is to evaluates the clinical effectiveness of a single-renal scallop custom-made stent-graft (TREO, Terumo Aortic, Sunrise, FL) to treat "hostile" AAA with mismatched renal arteries as actual standard of care in this Vascular Unit The main question it aims to answer are: if a dedicated devices could improve the results in the endovascular treatment of patients suffering to infrarenal abdominal aortic aneurism with a mismatched takeoff of the renal arteries. Participants responding to inclusion criteria will be treated as best clinical practice with a custom made device with a single scallop for the renal artery. The minimum follow-up requested, as standard clinical practice, was: 3-months, 12-18 months- and 5-years CTA; clinical and DUS examination at 6- and 12- and 36-months after the intervention and yearly thereafter. No comparison group was present.
NCT07184723
Symptomatic non-ruptured abdominal aortic aneurysms (snrAAA) remain a clinical challenge due to limited evidence and heterogeneous definitions and management strategies. Unlike ruptured AAAs, snrAAA lack large-scale population-based studies, primarily due to inconsistent application of standardised medical classifications (e.g., ICD-10) and international variability in definitions, diagnostic approaches, and treatment protocols. Optimal diagnostic pathways, preoperative risk assessments, and treatment strategies remain poorly defined, with minimal guidance from existing guidelines. This study aims to conduct a multinational cross-sectional online survey with optional retrospective validation to assess current opinions on an institutional scale regarding the definition and management of patients with snrAAA in Europe. All European vascular centres offering elective and emergency AAA repair are eligible to participate. Multiple survey entries from the same institution are not allowed. Centres are also invited to participate in a retrospective observational validation, reporting diagnostic and therapeutic details of their last five snrAAA cases.
NCT04526938
The primary objective of this study is to assess the use of a physician-modified Cook Alpha Thoracic Endovascular Graft in the repair of complex aortic aneurysms and thoracoabdominal aortic aneurysms and aneurysms secondary to aortic dissections in high-risk patients having appropriate anatomy. The primary intent of the study is to assess the safety and preliminary effectiveness of the device. Additionally, the study will assess renal function, radiation exposure, and quality of life.
NCT06710938
This study is designed as a single-center, prospective, single-arm, open-label, exploratory study. The objective is to evaluate the feasibility of Thoracoabdominal Artery Stent Graft System for endovascular treatment of Thoracoabdominal aortic aneurysms (TAAA).
NCT02016131
Re-hospitalization or re-intervention is sometimes necessary to treat type I and type III endoleaks after EVAR for its persistent increasing of pressure in aneurysm lumen. Color-coded quantitative digital subtraction angiography (CQDSA) provides an easy and quick way to post-process the traditional digital subtraction angiography (DSA) which converts the peak time of the maximal contrast medium intensity into a single polychromatic image. With the help of CQDSA, a quantitative evaluation of the endoleak hemodynamics and a risk analysis of the type I or type III endoleak could be performed during the EVAR procedure. This approach may offer an objective assessment of the needs for immediate re-intervention, conservative therapy or treatment endpoint in the future.
NCT02489539
The purpose of the study is to assess the safety and effectiveness of the GORE® EXCLUDER® Conformable AAA Endoprosthesis to treat an infrarenal aneurysm located in the abdominal aorta. Performance of the GORE® EXCLUDER® Conformable AAA Endoprosthesis will be judged by separate performance goals.
NCT05976711
An abdominal aortic aneurysm (AAA) is a pathological dilatation of the aorta in the belly which can rupture leading to bleeding within the belly. To prevent rupture elective surgery can be performed. Endovascular repair (EVAR) is a surgical intervention whereby a stent is inserted into the AAA to prevent it from further growth and rupture. Standard AAA management has several drawbacks. To start: maximum AAA diameter is used to determine upon timing of elective repair but is imprecise in predicting the risk of rupture resulting in an unmet clinical need. Secondly, EVAR outcome and complication occurrence remain unpredictable due to poor prediction ability of computed tomography (CT) and ultrasound (US) utilised in the follow-up protocol. Lastly, patients and physicians are being repeatedly exposed to cumulative radiation toxicity. All these drawbacks could be solved by trading the standard imaging modalities by magnetic resonance imaging (MRI). Within the MARVY, advanced MRI techniques are used to find out if standard imaging techniques could be replaced by MRI in three phases of the AAA management (surveillance, surgery planning and post-operative follow-up). The two most important MRI techniques that will be used are 4D flow MRI and dynamic contrast enhanced (DCE) MRI which give respectively information about the blood flow within the AAA and perfusion of the aortic wall.
NCT05896397
The purpose of this study is to evaluate the safety and performance of Cook's various Custom-Made Stent-graft Devices (CMD) used for endovascular treatment of the aorta and related diseases by collecting information on the real-world use of the devices. The study results will be used to support the continuation of the CMDs on the market. In addition, the study will support the manufacturers obligation for post market product surveillance as well as Cook's technology development.