Loading clinical trials...
Loading clinical trials...
The Effects of Practitioner Anthropometric Differences and Bed Level on CPR Quality in Pediatric Cardiopulmonary Resuscitation: A Simulation-Based Study
High-quality chest compressions are critical for outcomes after pediatric cardiac arrest, yet rescuer ergonomics and bed height may adversely affect compression quality and fatigue. This randomized crossover simulation study will evaluate how four different bed-height settings influence pediatric CPR quality and rescuer biomechanics. Pediatric emergency medicine residents will perform 2-minute chest-compression-only CPR on a pediatric manikin placed on a hospital bed under four bed-height conditions in randomized order across separate sessions. CPR quality metrics from the manikin's feedback system, rescuer fatigue, physiologic responses, and arm angle over time will be compared to identify an ergonomically optimal bed-height approach.
Background and Rationale In-hospital pediatric cardiac arrest requires rapid delivery of high-quality CPR. Compression depth, rate, and full chest recoil are key determinants of effective CPR, but maintaining these targets can be challenging due to rescuer posture, bed height, and fatigue. While step-stool use and provider height have been associated with CPR quality in some contexts, there is limited evidence on how bed-height settings-especially anthropometry-based adjustments-affect pediatric CPR performance and rescuer biomechanics over time. Objective and Hypothesis Objective: To determine the effect of four bed-height conditions on pediatric CPR quality and rescuer biomechanics in a controlled simulation setting. Hypothesis: Anthropometry-based and/or self-selected bed height will improve CPR quality (e.g., correct depth and recoil) and reduce perceived exertion compared with a fixed standard bed height. Study Design This is a prospective, randomized, within-subject crossover simulation study. Each participant completes CPR under four bed-height conditions, with the order randomized to reduce learning and fatigue bias. Sessions are performed on separate days. Participants Eligible participants are volunteer pediatric emergency medicine residents (or comparable clinicians) who are trained in pediatric basic/advanced life support. Individuals with conditions that could limit safe performance of chest compressions (e.g., significant cardiopulmonary or musculoskeletal disorders) are excluded. Anticipated enrollment is approximately 25 participants. Interventions (Bed-Height Conditions) Participants will perform chest-compression-only CPR under four bed-height conditions: Fixed standard bed height (e.g., 58 cm). Anthropometry-based height A: bed height aligned to a predefined landmark (e.g., patella midpoint). Anthropometry-based height B: bed height aligned to a second predefined landmark (e.g., a point derived from the distance between patella and anterior superior iliac spine \[ASIS\]/spina iliaca anterior superior \[SIAS\], such as the lower one-third point). Self-selected height: participant chooses the bed height they feel is optimal. (Replace the anthropometric definitions above with your exact operational definitions.) Procedures A pediatric manikin with objective CPR measurement capability (e.g., Laerdal Little Junior QCPR) is placed on a hospital bed. For each condition, the participant performs 2 minutes of continuous chest compressions as a single rescuer. No metronome and no real-time corrective feedback are provided during the compression period (unless your protocol uses feedback; then adjust this sentence). Standardized hand placement and compression position are instructed. Outcome Measures Primary Outcome Correct Compression Depth (%) during each 2-minute session (manikin-derived). Secondary Outcomes Average compression depth (mm) Average compression rate (compressions/min) Correct chest recoil / release (%) Composite CPR quality scores (e.g., compression score, total score), as available from the manikin system Rescuer fatigue: Borg Rating of Perceived Exertion immediately after each session Physiologic response: heart rate and oxygen saturation (SpO₂) measured pre- and post-session (and change from baseline) Rescuer biomechanics: arm/upper-limb angle measured from video at standardized time points during compressions (e.g., 0, 30, 60, 90, 120 seconds) Statistical Considerations Outcomes will be compared across bed-height conditions using within-subject methods (e.g., linear mixed-effects models with participant as a random effect). Pairwise comparisons will be adjusted for multiple testing. Exploratory analyses may evaluate whether participant anthropometry (height, BMI, etc.) modifies the effect of bed height on CPR quality. Ethical Considerations This is a simulation-based study with no patient involvement and minimal risk. Participants may stop at any time due to discomfort or fatigue. The study has ethics approval from \[Akdeniz Üniversitesi Bilimsel Araştırma ve Yayın Etiği Kurulu, Approval Number: 875 /09/28/2025\] and all participants provide informed consent.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
Yes
Akdeniz University Hospital / Faculty of Medicine Hospital - Dept. of Pediatrics
Antalya, Antalya, Turkey (Türkiye)
Start Date
September 28, 2025
Primary Completion Date
February 1, 2026
Completion Date
April 1, 2026
Last Updated
January 9, 2026
25
ESTIMATED participants
Fixed Standard Bed Height (58 cm)
OTHER
Anthropometry-Based Bed Height (Patella Midpoint)
OTHER
Anthropometry-Based Bed Height (Lower One-Third Patella-ASIS)
OTHER
Self-Selected Bed Height
OTHER
Lead Sponsor
Akdeniz University
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT03220269