Loading clinical trials...
Loading clinical trials...
In 2022, data from the UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) indicated that Total Hip Replacement (THR) is the most commonly performed orthopaedic joint surgery. The NJR has observed that between 10 and 20% of hip implants require revision within the first 10 years. The main reasons for these revisions include implant fractures, joint incompatibility, aseptic loosening, dislocation and wear of the polyethylene (PE) insert. To address this problem, highly cross-linked polyethylene (HXLPE) inserts have been developed. Cross-linking helps to limit wear on polyethylene prostheses in total hip arthroplasty. However, there are concerns about the loss of elasticity of HXLPE and oxidation after implantation. A new generation of inserts based on highly cross-linked polyethylene (irradiation dose ≥100 Kgy), enriched with vitamin E, has been developed. This PE, called ECIMA, was developed to maintain mechanical properties, minimise PE wear and improve long-term oxidation resistance. In the HAS evaluation report on highly cross-linked polyethylene inserts dated 24 January 2023, data from the literature show less wear of highly cross-linked polyethylene compared to conventional polyethylene. Nevertheless, the use of highly cross-linked polyethylene is not yet the gold standard. Furthermore, the data in the literature mainly concern single-mobility cups but not double-mobility cups. Finally, new imaging protocols now make it possible to assess the wear of prosthesis materials more accurately. In this context, it seems appropriate to conduct a French study comparing double-mobility cups containing highly cross-linked polyethylene or conventional polyethylene inserts.
In 2022, data from the UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) indicated that total hip arthroplasty or Total Hip Replacement (THR) is the most commonly performed orthopaedic joint surgery. THR involves replacing worn and damaged areas of cartilage in the hip with artificial parts of similar shape and size. A total hip replacement consists of two parts: * A part designed to replace the head of the femur: a spherical prosthesis mounted on a stem that is inserted into the femur; * A part designed to replace the acetabulum: the acetabular cup. There are single-mobility cups and double-mobility cups, where an insert is positioned on the metal head inside a single-mobility cup. Introduced in the 1960s by Sir John Charnley, UHMWPE (Ultra High Molecular Weight Polyethylene) remains the most widely used material for inserts in 2024. The NJR has observed that between 10 and 20% of hip implants require revision within the first 10 years. The main reasons for these revisions include implant fractures, joint incompatibility, aseptic loosening, dislocation and wear of the polyethylene (PE) insert. To address this problem, highly cross-linked polyethylene (HXLPE) inserts have been developed. Cross-linking helps to limit wear on polyethylene prostheses in total hip arthroplasty. However, there are concerns about the loss of elasticity of HXLPE and oxidation after implantation. A new generation of inserts based on highly cross-linked polyethylene (irradiation dose ≥100 Kgy), enriched with vitamin E, has been developed. This PE, called ECIMA, was developed to maintain mechanical properties, minimise PE wear and improve long-term oxidation resistance. In the HAS evaluation report on highly cross-linked polyethylene inserts dated 24 January 2023, data from the literature show less wear of highly cross-linked polyethylene compared to conventional polyethylene. Nevertheless, the use of highly cross-linked polyethylene is not yet the gold standard. Furthermore, the data in the literature mainly concern single-mobility cups but not double-mobility cups. Finally, new imaging protocols now make it possible to assess the wear of prosthesis materials more accurately. In this context, it seems appropriate to conduct a French study comparing double-mobility cups containing highly cross-linked polyethylene or conventional polyethylene inserts. In the principal investigator's current practice, prostheses with conventional PE inserts are used for patients aged 70 or over, while prostheses with highly cross-linked PE inserts are used for patients under 70. However, this age-based choice is modulated favourably or unfavourably by two other parameters: the patient's medical history and general condition.
Age
55 - 80 years
Sex
ALL
Healthy Volunteers
No
Hôpital Privé Jean Mermoz
Lyon, France, France
Start Date
November 15, 2025
Primary Completion Date
August 31, 2036
Completion Date
August 31, 2036
Last Updated
October 3, 2025
96
ESTIMATED participants
ECIMA CORIN
DEVICE
CORIN
DEVICE
Lead Sponsor
GCS Ramsay Santé pour l'Enseignement et la Recherche
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions