Finding studies
Finding studies
Take this into the appointment.
Saves the questions and what to expect into your notes, next to the visit they belong to.
Lead
Hospitales Universitarios Virgen del Rocío
With
This is a prospective, crossover pilot study designed to evaluate the safety, efficacy, and tolerability of a novel respiratory therapy device, ELECTROVEST, in adult patients diagnosed with chronic respiratory diseases featuring bronchial hypersecretion, such as COPD, bronchiectasis, cystic fibrosis, and asthma. ELECTROVEST is a wearable vest that integrates high-frequency chest wall oscillation (HFCWO) with surface neuromuscular electrical stimulation (NMES). This dual-action therapy aims to enhance airway clearance while also stimulating respiratory musculature. The study will enroll 20 patients, using a non-probabilistic, intentional sampling strategy. Each participant will undergo two intervention phases, acting as their own control. The phases are separated by a 30-day washout period to minimize carryover effects. Phase 1 (ELECTROVEST intervention): Participants receive standard fluid and aerosol therapy followed by vibratory therapy delivered by the ELECTROVEST device. Sessions include: Warm-up phase: 2 minutes at 4 Hz Active treatment: 16 minutes at 8 Hz Cool-down phase: 2 minutes at 4 Hz Phase 2 (Control intervention): Participants receive the same fluid and aerosol therapy, followed by vibratory therapy using standard HFCWO systems (The Vest® Model 105 ). The session follows: Warm-up: 2 minutes at 13 Hz Active treatment: 16 minutes at 20 Hz Cool-down: 2 minutes at 13 Hz Both interventions are conducted under clinical supervision. The effects will be assessed through pulmonary function tests, respiratory muscle strength, sputum analysis, oxygenation and hemodynamics, patient-reported symptoms, and blood biomarkers. Pulmonary function and muscle strength will be measured before and 10 minutes after each intervention (FEV₁, DLCO, PImax, PEmax, SNIP). Sputum production and quality will be assessed by weight and purulence (Murray scale). Exercise tolerance will be evaluated via the 6-minute walk test. Blood markers will be obtained before and 48 hours after each intervention, including: Creatine phosphokinase (CPK-MM, CPK-BB) C-reactive protein (CRP) Peripheral leukocyte count Creatinine, urea, albumin Estimated glomerular filtration rate (eGFR) Venous lactate Monitoring during sessions includes: Oxygen saturation (SpO₂) Heart rate Discomfort and dyspnea assessed via a visual analogue scale (VAS, 0-10), recorded at baseline, 5 minutes, and post-treatment. This trial aims to identify physiological responses, tolerability, and short-term safety signals, while generating preliminary data on the potential dual utility of the ELECTROVEST device as a mucociliary clearance and respiratory muscle stimulation therapy.
Age
16–any
Sex
ALL
Healthy volunteers
Not accepted
