Closed Loop Oxygen Control in INtubated Critically Ill Patients - CLOC-IN
The deleterious effects of alveolar hyperoxia and (severe) hyperoxaemia are well described. Achieving safe and efficient oxygenation may be challenging. The hypothesis of the present study is that closed-loop oxygen control in intubated and mechanically ventilated critically ill patients improves oxygen administration compared with standard manual oxygen titrations. A single-blind, randomised crossover clinical trial assessing the efficacy and safety of the use of a closed-loop oxygen control versus manual oxygen titration in patients receiving mechanical ventilation has been designed. Patients will be randomised to receive first either closed-loop oxygen control (CLOC) or manual oxygen titration (MOT). The percentage of time spent in optimal and sub-optimal SpO2 (oxygen saturation by pulse oximetry) ranges will be calculated for each period.
The deleterious effects of alveolar hyperoxia and (severe) hyperoxaemia are well described. A safe and efficient oxygenation should be achieved. However, from a practical point of view, this may require frequent manual adjustments of the inspired oxygen, which might be unfeasible, especially in high-demand periods. Several automatic oxygen systems have been tested in non-intubated patients. The hypothesis of the present study is that closed-loop oxygen control in intubated and mechanically ventilated critically ill patients improves oxygen administration compared with standard manual oxygen titrations. Thus, the objective of the study is to compare the percentage of time spent in a predefined optimal SpO2 range between closed-loop oxygen control and manual oxygen titration. A single-blind, randomised crossover clinical trial assessing the efficacy and safety of the use of a closed-loop oxygen control versus manual oxygen titration in patients receiving mechanical ventilation has been designed. Once included, patients will be randomised to receive first either closed-loop oxygen control (CLOC) or manual oxygen titration (MOT). Every period will last for 4h. Clinical and respiratory variables will be recorded. A memory box will be connected to the patient's ventilator. This device will record ventilator parameters, including FiO2 and SpO2. To assess the outcome, the percentage of time spent in optimal and sub-optimal SpO2 ranges will be calculated for each period.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
Parc Tauli Hospital Universitary
Sabadell, Barcelona, Spain
Start Date
April 1, 2023
Primary Completion Date
March 1, 2025
Completion Date
March 1, 2025
Last Updated
February 17, 2025
46
ESTIMATED participants
closed-loop oxygen control (CLOC)
DEVICE
2. manual oxygen titration (MOT)
DEVICE
Lead Sponsor
Parc Taulí Hospital Universitari
NCT06996197
NCT02907008
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions