Participants. Critically ill patients (n: 30; aimed recruitment of equal numbers of men and women) aged 18 years or older admitted to the St. Michael's Hospital, Unity Health Toronto, Ontario, Canada.
Inclusion criteria:
* patients intubated for more than 12 hours
* exposed to sedation for at least 6 hours
* with a sedation-agitation score ≤ 4
* and corresponding to one of the following categories based on bedside inspection of ventilator waveforms:
1. patients on assist-control ventilation having reverse triggering at clinical settings (n: 15).
2. patients on assist-control ventilation without reverse triggering at the clinical settings (n: 15).
Exclusion criteria:
* primary severe neurological disorders
* previous lung transplant
* contraindications for esophageal catheter insertion
* current use of continuous neuromuscular blocking agents at the time of the study procedure
* severe metabolic acidosis (pH \< 7.25) at the time of study procedure. Study design. Briefly, first the ventilator Vt is set at 6 ml/kg of predicted body weight (PBW) (i.e., clinical practice recommendation) and either a up to 30sec-long (or two inspiratory efforts) end-expiratory occlusion maneuver will be performed on the ventilator or the patient will be switched to pressure support for 30 - 60 sec (based on discussion with the clinical team) to assess the presence or absence of patient's intrinsic RR.
Secondly, the influence of the ventilator RR on both the occurrence of reverse triggering and the level of effort associated with the reverse triggered breath will be assessed. In random order the ventilator RR will be modified from 6 bpm below up to 6 bpm above the clinical RR in steps of 2 bpm every 1 minute (Figure 1). A 1-minute stage at the patients clinical settings of ventilation in-between each step will be performed to minimize changes in PaCO2.
Thirdly, the influence of the Vt set on the ventilator on both the occurrence of reverse triggering and the level of effort associated with the reverse triggered breath will be assessed. The ventilator Vt will be set to 5 ml/kg PBW, 7 and 8 ml/kg PBW in random order and for each volume, repeat the sequence described in the paragraph above. A 1-minute clinical settings ventilation will be performed in-between each step to minimize changes in PaCO2.
Next, the patient will be returned to their initial clinical settings. Another end-expiratory occlusion of up to 30 seconds (or two inspiratory efforts) or switch the patient to pressure support for 30 - 60 sec (based on discussion with the clinical team) will be performed to search for an intrinsic RR (i.e., intrinsic respiratory drive). If an intrinsic respiratory rate ≥8 breaths per minute is present and P/F ratio is ≥150, it will propose to the clinician to place the patient in pressure support at a level preferred by clinicians for 5 minutes. If the patient tolerates well 5 minutes in pressure support, it be will propose to the clinician to maintain the patient in pressure support ventilation.
The steps described above will be aborted at any point if SpO2 drops below 85% for at least two minutes, mean arterial pressure drops below 60 mmHg, or plateau pressure \>35 cmH2O.
Additionally, the ventilator waveforms and electroencephalography (EEG) will be recorded continuously for the next 24 hours to investigate whether the presence of intrinsic RR was associated with changes in the ventilation mode by the clinician and brain activity.