Comparison of Real-time CGMS With Intermittently-scanned CGMS in Adolescents and Adults With Type 1 Diabetes Mellitus: an Open Label Randomised Control Cross Over Study
Type 1 Diabetes Mellitus (T1DM) is characterized by absolute insulin deficiency. Despite multiple daily insulin injections, glycemic targets are usually not achieved in T1DM patients.Use of continuos glucose monitoring system (CGMS) is associated with improvement in glycemic control and reduction in glycemic variability in T1DM subjects. real-time CGMS (rt-CGMS) and intermittently scanned CGMS (is-CGMS) are the newer CGMS technologies. Previous studies have shown that in T1DM patients rt-CGMS is better than is-CGMS for glycemic control and reducing hypoglycemic episodes in patients with impaired awareness of hypoglycemia, but in patients with normal hypoglycemic awareness this is not well established. This study is a randomized control clinical cross over study of 6 months duration in patients of T1DM having normal hypoglycemic awareness, with age 15-40 years with a HbA1c range of 8-12%. Following a training period of 2 weeks, 80 participants will be randomized into 3 arms in a ratio of 1:1:2 in rt-CGMS, is-CGMS and SMBG (self monitoring of blood glucose) arms, respectively. For the first two groups Medtronic Guardian Connect Sensor 3 and Abott Freestyle Libre Sensor 2will be applied for 2 weeks, respectively; followed by a crossover at 3 months withapplication of is-CGMS and rt-CGMS, respectively in these groups for a further 2 weeks period. For rest of the study duration these patients in the rt-CGMS and is-CGMS group will be monitored through SMBG. The 3rd SMBG group will act as control. Short term blood glucose control will be assessed by Fructosamine assay in the 2 CGMS groups and long term control by HbA1C.
Type 1 Diabetes Mellitus (T1DM) is characterized by absolute insulin deficiency. Despite multiple daily insulin injections, glycemic targets are usually not achieved in T1DM patients. Use of continuos glucose monitoring system (CGMS) is associated with improvement in glycemic control and reduction in glycemic variability in T1DM subjects. Real-time CGMS (rt-CGMS) and intermittently Scanned CGMS (is-CGMS) are the newer CGMS technologies. Previous studies have shown that in T1DM patients rt-CGMS is better than is-CGMS for glycemic control and reducing hypoglycemic episodes in patients with impaired awareness of hypoglycemia, but in patients with normal hypoglycemic awareness this is not well established. This study is a randomized control clinical study of 6 months duration in patients of T1DM having normal hypoglycemic awareness, with age 15-40 years with a HbA1c range of 8-12%. Following a training period of 2 weeks, 80 participants will be randomized into 3 arms in a ratio of 1:1: 2 into rt-CGMS, is-CGMS arms and SMBG(Self Monitoring of Blood Glucose) arms respectively. For the rt-CGMS group Medtronic Guardian Connect sensor 3 will be applied for 2 weeks and and for is-CGMS group Free Style Libre will be applied for 2 weeks. The participants randomized into the 3rd group shall do self monitoring of blood glucose(SMBG) throughout the study duration of 6 months. Those participants randomized into rt-CGMS and is-CGMS groups after the end of 2 weeks will also monitor their blood glucose by SMBG till the end of 3 months.The frequency of SMBG for all these groups would be - 4 times a day( premeal blood glucose and one post meal blood glucose on rotational basis) on weekdays and 7 times on Sundays(3 times pre meals, 3 times 2 hrs post meals and once at 3 am). At the end of 3 months participants in the rt-CGMS group will undergo crossover to is-CGMS group and vice versa whereas participants in SMBG group will remain in the same arm till the end of the study(6 months).Short term blood glucose control will be assessed by Fructosamine assay after 2 weeks of CGMS application and long term control by HbA1C at the end of 3 months and 6 months. All glycemic parameters(like Time in Range, Time below Range and Time in Range will be compared in both CGMS groups before and after cross-over and both these arms will be compared with SMBG for all the outcomes.Quality of life will also be assessed in these groups by using QOLID questionnaire.
Age
15 - 40 years
Sex
ALL
Healthy Volunteers
No
Post Graduate Institute of Medical Education and Research
Chandigarh, India
Start Date
August 10, 2023
Primary Completion Date
March 1, 2024
Completion Date
March 1, 2024
Last Updated
August 21, 2023
80
ESTIMATED participants
Medtronic Guardian Connect Sensor 3
DEVICE
Abott Freestyle Libre Sensor
DEVICE
Self blood Glucose monitoring by a glucometer
OTHER
Lead Sponsor
Post Graduate Institute of Medical Education and Research, Chandigarh
NCT05777330
NCT03811470
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT07319286