22 healthy males between the ages of 20 and 45 will be recruited for this study. All subjects will receive pre-study informed consent. All experimental procedures were designed with the Helsinki declaration in mind and approved by the local ethics committee. In all subjects, whole body vibration(WBV) and isolated tendon vibration will be applied before, after, and during sympathetic activation maneuvers. Reflex responses induced by WBV and isolated tendon vibration will be recorded by surface electromyography (EMG) from the right soleus muscle. Latency calculation will be made using the "Cumulative averaging method".
Mental arithmetic task and cold stress test will be applied as sympathetic activation maneuver. For the mental arithmetic task, the subject is asked to mentally subtract a two-digit number from a four-digit number and respond within five seconds. This arithmetic calculation is repeated for different numbers. This test is continued for two minutes. For the cold stimulation test, subjects are asked to dip their right hand into 2-4 degrees cold water up to the elbow and hold it in the water for two minutes. At this time, either WBV or tendon vibration will be applied. After a ten-minute break, a cold stimulation test will be applied to the left hand and the subject will be asked to do mental arithmetic calculations simultaneously. Meanwhile, other vibrations will be used. The sympathetic response will be evaluated by heart rate and sympathetic skin response.
Whole body vibration will be applied to the right leg while subjects are sitting with their knee, hip, and ankle joints in a 90-degree position.
The left leg will rest on a vibration-isolated platform. During this position, he will be asked not to voluntarily contract the calf muscle. The vibration will be applied with the PowerPlate® Pro5 WBV (London UK) device. The vibration amplitude will be 2.2 mm. The vibration frequency will be 30, 35, 40, and 45 Hz. Each vibration frequency will be applied for 30 seconds. A 5-second rest period will be applied between 30-second vibrations. Piezo-electric accelerometer (LIS344ALH, full-scale of ± 6 g, linear accelerometer, ECOPACK®, Mansfield, TX, USA) will be fixed on the WBV device platform for reflex latency calculation. For tonic vibration 100, 135, 150, and 180 Hz vibrations will be applied to the Achilles tendon. 30 seconds of vibration will be applied at each frequency. A direct current (DC) motor vibrator will be used to apply this vibration (Bosch™, amplitude 2 mm, motor speed 5000-20000 / min). A piezo-electric accelerometer (LIS344ALH, full-scale of ± 6 g, linear accelerometer, ECOPACK®, Mansfield, TX, USA) will be placed on the skin of the Achilles tendon to calculate the tonic vibration reflex latency. Superficial EMG recordings will be taken from the right soleus muscle with the bipolar technique. A pair of self-adhesive Ag/AgCl (KENDALL® Coviden, Massachusetts, USA) electrodes will be attached to the skin. The electrodes on the soleus will be positioned according to the SENIAM protocol. The ground electrode will have adhered to the right lateral malleolus. Before the electrodes are attached to the skin, if there are hairs on the skin, they will be shaved and the oil layer on the skin will be cleaned with alcohol cotton. In order to increase the moisture of the skin, ECG gel will be applied to the skin area where the electrode will be attached. Superficial EMG recordings will be taken with a PowerLab ® (ADInstrument ADInstruments, Oxford, UK) data recorder with a sample rate of 40 kHz.
EMG recordings will be analyzed offline with LabChart7 Pro® version 7.3.8 (ADInstrument, Oxford, UK). The acceleration measurement data will be recorded with the PowerLab (ADInstrument London) data logger simultaneously with the EMG recording. Acceleration recording will be made with a sample rate of 40 kHz. Simultaneously, heart rate and sympathetic skin response will be captured with a Biopac (Biopac System Inc CA) data recorder at a rate of 20 kHz.