The goal is to evaluate the trends in MouthLab parameters (respiration rate, temperature, pulse rate, electrocardiogram rhythm, blood pressure, oxygen saturation heart rate and basic lung function measures) in patients with decompensated heart failure and how these measurements change in response to decongestion. The research will test the ability of the MouthLab device to predict clinical decompensation in patients with known heart failure and to reduce the number of hospital readmissions based on the treatment guided by MouthLab device data.
Heart failure (HF) is becoming increasingly recognized with an estimated worldwide prevalence of \>37.7 million individuals. In the United States alone, there are over 5 million patients with HF which is expected to increase to over 8 million by 2030. Despite advances in medical therapies and technology, HF remains the leading cause of hospitalization among adults and the elderly. By 2030, the medical costs of HF are expected to rise from $20.9 billion to $53.1 billion, with nearly 80% of the projected increased expenses attributes to hospitalization costs. As such, it is imperative to develop new technologies and treatment options to impact the HF epidemic. The majority of HF hospital admissions are due to volume overload. Stiffened and/or weakened myocardium predisposes patients to the accumulation of extracellular fluid resulting in increased intracardiac filling pressures and symptoms of congestion (edema, dyspnea and orthopnea). Accurate assessment of a patient's volume status remains clinically challenging at times. While there have been technological advances in the outpatient monitoring of volume status through thoracic impedance and pulmonary artery pressure monitoring, there are no validated, non-implantable options for monitoring volume status outside of the physical exam. Aidar Health's MouthLab device is a non-invasive, hand-held, home monitoring tool that measures multiple medical parameters such as - Temperature, Blood Pressure, Heart Rate, Heart Rate Variability, Pulse Rate, SpO2, single-lead ECG, Respiratory Rate, Breathing Pattern/Respiratory Flow Cycle Morphology, and basic lung functions (FEV1, FVC, FEV1/FVC, PEF) in 30 seconds. The investigators believe that the MouthLab device holds the potential to identify changes in volume status through measurements such as pulse rate, oxygen saturation, respiratory flow and lung function and accurately predict decompensation in patients with chronic HF. The investigators propose the following outline of clinical studies to evaluate the utility of the MouthLab device in HF.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
WakeMed Health and Hospitals
Raleigh, North Carolina, United States
Start Date
October 1, 2022
Primary Completion Date
October 1, 2022
Completion Date
October 20, 2022
Last Updated
October 24, 2022
MouthLab Device
OTHER
Lead Sponsor
WakeMed Health and Hospitals
NCT07484009
NCT07191730
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions