This is a multi-center, single-blind, randomized, controlled trial. two hundred and ninety six patients with solid pancreatic lesions referred for EUS guided fine needle biopsy will be randomly assigned to two groups. For group A which will be used with 22G EUS Procore fine needle biopsy device, the pass sequence is WS-SNP-WS-SNP technique. For group B with 22G EUS Procore fine needle biopsy device, the pass sequence is SNP-WS-SNP-WS. All procedures will be performed by experienced echo-endoscopists, and the patients and assessors (cytologists and pathologists) will be blinded during the entire study. The primary outcome measure is the diagnosis yield. Secondary outcome measures are specimen quality.