Study design: prospective, randomized, cross-over study. Study population: moderate to severe COPD patients, long-term users of nocturnal non-invasive ventilation for chronic hypercapnic respiratory failure. Inclusion criteria: age\<85 years; presence of tidal expiratory flow limitation in the supine position at an expiratory positive airway pressure of 4 cmH2O. Exclusion criteria: COPD exacerbation within the past two months; acute illness; clinical instability.
Study protocol: Patients were studied in the hospital over 2 non-consecutive nights while using either fixed or automatic EPAP.
Ventilation strategy: pressure-controlled NIV was delivered using a non-commercial version of BiPAP Synchrony Ventilator (Philips-Respironics) via an unvented facial mask (AMARA, Philips-Respironics). The ventilator evaluated the presence of tidal expiratory flow limitation by the forced oscillation technique. In the automatic-EPAP mode, the ventilator continuously adjusted EPAP to the minimum level able to abolish tidal expiratory flow limitation, with a minimum EPAP of 4 cmH2O and keeping the pressure support constant.
Measurements: During each study night, the investigators recorded transcutaneous partial pressure of carbon dioxide and oxygen saturation (TOSCA, Radiometer) continuously. Airway opening pressure, flow and volume tracings were exported from the ventilator. Full laboratory polysomnography (Alice5, Philips-Respironics) was performed according to the American Academy of Sleep Medicine recommendations.
Data analysis: the investigators compared parameters from the two nights using Wilcoxon signed-rank test. P-values \<0.05 were considered statistically significant.