The purpose of this study was to compare the changes of cardiac function within 1month in pacemaker-dependent patients between LBBP and RVOP. A single-center prospective random controlled clinical study was conducted in 60 patients with bradycardia indications. 30 patients underwent RVOP and 30 patients underwent LBBP. The changes of BNP, echocardiogram and speckle-tracking echocardiagraphy, six minutes walk test and quality of life were compared between the two groups before and within 1month. The etiology of pacemaker implantation included high atrioventricular block, atrial fibrillation with slow arrhythmia. Implantation procedures: Left bundle branch pacing was achieved by trans-interventricular septum method in the basal ventricular septum and performed by using the Select pacing 3830 lead(Medtronic Inc, USA) delivered through a fixed sheath(7F C315 HIS, Medtronic Inc, USA). During implantation, a unipolar configuration is used for pacing and recording. The delivery sheath was inserted through left subclavian vein into atrial side of the tricuspid valve to mark His bundle potential under right anterior oblique(20°) fluoroscopic view. As a marker in His bundle region, the sheath with the lead tip was further advanced towards the right side of the ventricular septum approximately 1.5-2cm, and paced QRS morphology showing left bundle branch block(LBBB) at output of 2V/0.4ms. When the sheath with the lead tip screwed to the left side of the septum, paced QRS morphology changed from LBBB to right bundle branch block(RBBB), a gradual change of the notch morphology("W" waveform) in lead V1 gradually shifted and finally disappeared.Another active electrode is implanted in the right auricle.Patients with RVOP: The right ventricular pacing lead was positioned in the low intervals of right ventricular outflow tract, and atrial active lead was positioned at right auricle. BNP was measured routinely before implantation and reexamined on 1 day and 1month after pacemaker implantation.Twelve-lead ECG were recorded including QRS duration, QRS amplitude and QT interval. Echocardiography data were measured by conventional transthoracic echocardiography system including left atrial anteroposterior dimension, left atrial transverse dimension, left atrial vertical dimension, e', peak E-wave velocity, peak A-wave velocity, E/A, E/e', left atrial ejection fraction (LAEF), left ventricular ejection fraction (LVEF), velocity-time integration of aortic blood flow(VTI). Left atrial strain and strain rate were measured by speckle-tracking echocardiography(STE).We also measure the six minutes walk test and quality of life in all patients before and after implantation in 1month.