Loading clinical trials...
Loading clinical trials...
An Observer Blinded Point-of-care Gastric Ultrasound Analysis of the Gastric Emptying Time of Orange Juice With and Without Pulp
Preoperative fasting guidelines for anesthesia recommend waiting two hours after ingesting a clear liquid and six hours after ingesting a light meal. Due to the presence of pulp, orange juice is considered a light meal by current guidelines which means a patient must wait six hours before undergoing general anesthesia. This study will use ultrasound of stomach of healthy volunteers to determine if the presence of pulp actually increases the transit time for orange juice.
Healthy volunteers will be solicited (medical students and attending anesthesiologists) to participate in the study. Volunteers will participate in two sessions, one for orange juice without pulp and one for orange juice with pulp. Participants will be NPO after midnight and will be asked to arrive at approximately 8 am. Upon arrival for females of child bearing age, a urine pregnancy test will be performed and they will be discreetly informed of the results of the test. After, all patients will have their gastric volume assessed using point-of-care ultrasound to ensure the study team is able to adequately identify their stomach as well as to ensure the stomach is empty. After measurements are made, participants will drink 12 oz (approximately 350 mL) of either orange juice with or without pulp. Two hours after finishing the juice they will again undergo point-of-care gastric ultrasound scanning. Images will be saved and will be examined by a blinded independent anesthesiologist. The study will entail two visits each lasting for approximately 3 hours. Point-of-care gastric ultrasound will be performed using a low-frequency curvilinear ultrasound probe. The exam will be performed on a stretcher with the participant in both the supine and right lateral decubitus (RLD) position. The goal of point-of-care gastric ultrasound is to obtain an image of the gastric antrum. The low-frequency large curvilinear probe is placed in the epigastric area in a sagittal or parasagittal plane immediately inferior to the patient's xiphisternum with the orientation marker directed cephalad. Image optimization requires scanning in an anterior and cephalad direction toward the liver by tilting the tail of the probe toward the feet. A qualitative analysis will occur first to rule out solid contents in the stomach. Once confirmed, the gastric antral cross-sectional area (CSA) will be measured in the RLD position. Correlation has been shown between CSA and total gastric fluid volume. A gastric volume less than 1.5 mL/kg is considered consistent with fasting. The study will be repeated for both orange juice with and without pulp.
Age
18 - 65 years
Sex
ALL
Healthy Volunteers
Yes
Thomas Jefferson University Hospital
Philadelphia, Pennsylvania, United States
Start Date
November 19, 2019
Primary Completion Date
December 17, 2019
Completion Date
December 17, 2019
Last Updated
March 18, 2020
14
ACTUAL participants
Point of care gastric ultrasound
OTHER
Lead Sponsor
Thomas Jefferson University
NCT06430957
NCT06346132
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions