Loading clinical trials...
Loading clinical trials...
The Relationship Between the Tympanostomy Tube Extrusion Time & Viscosity
Studies have focused on the factors that influence tympanostomy tube (TT) extrusion may contribute to the management of OME. In this study the investigators aimed to assess the correlation between the TT extrusion time and viscosity of the middle ear fluid. 33 patients scheduled for TT insertion included in the study. During the paracentesis, fluid from the middle ear was obtained, and the viscosity was measured with a viscometer. After the surgery, patients were controlled monthly until the tubes were seen extruded.The analysis of the correlation between tube extrusion time and viscosity was insignificant (p \>0.05).
45 patients were evaluated in the outpatient clinic of the Bezmialem Vakif University Department of Otorhinolaryngology. OME was diagnosed by endoscopic-otoscopic examination findings and type-B tympanograms. Patients who do not have a previous history of TT insertion and retraction pocket included in the study. They were all scheduled for Shepard TT insertion. 12 patients were excluded for not coming to their postoperative controls properly. Total of 33 patients' data were analyzed in the end. During the paracentesis, myringotomy incision was done at the anteroinferior quadrant. Fluid from the middle ear was obtained by using 22 gauge syringe, and the viscosity was measured with a viscometer. Since the viscosity in most patients was mucoid in appearance, the patients were subdivided into two groups according to median viscosity level to determine whether higher or lower viscosity of the effusion impacted tympanostomy tube extrusion time. Patients with an effusion below and above the median viscosity value of 439 centipoise (cP) were assigned to Group 1 and 2, respectively. After the surgery, patients were controlled monthly until the tubes were seen extruded.Brookfield DV-II+ProCP Viscometer (Brookfield Engineering Laboratories, Inc., Massachusetts, USA) was used for viscosity measurements. This viscometer was able to measure the viscosity of fluid samples as small as 0.5 ml. The results of the viscosity measurements were recorded as cP units. The patients were investigated for any correlation between the viscosity level of the effusion and extrusion time of the TT. Descriptive statistics were presented as mean and standard deviation. T-test was used to estimate the correlation between the parameters. Mann-Whitney U Test was used to compare the two groups. Statistical analyses were conducted with the IBM SSPS 22.0 program. Significance level was set at 0.05 for all tests. All the procedures were approved and performed in accordance with the ethical standards of the relevant national and institutional guidelines on human experimentation and with the Helsinki Declaration of 1975, as revised in 2008. Permission for the study was obtained from Institutional Ethics Committee.
Age
2 - 53 years
Sex
ALL
Healthy Volunteers
No
Bezmialem Vakif University
Istanbul, Fatih, Turkey (Türkiye)
Start Date
January 15, 2018
Primary Completion Date
June 15, 2019
Completion Date
June 25, 2019
Last Updated
August 8, 2019
33
ACTUAL participants
Middle ear fluid viscosity
OTHER
Tympanostomy tube extrusion time
OTHER
Lead Sponsor
Bezmialem Vakif University
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT07122999