Finding studies
Finding studies
Take this into the appointment.
Saves the questions and what to expect into your notes, next to the visit they belong to.
Lead
Jaeb Center for Health Research
CGM offers the opportunity to improve glycemic control, including a reduction in hypoglycemia. Unlike home blood glucose monitors, CGM is not intended to be used directly for making therapy adjustments and is an adjunctive device to supplement information obtained from a standard blood glucose monitor. However, although the labeling for CGM requires a BGM measurement before making a therapy adjustment, many CGM users often decide on a meal bolus based on CGM alone. A study comparing CGM used solely as an adjunctive device, as per the FDA labeling, versus CGM used largely in lieu of BGM measurements would provide valuable data. Since many individuals with T1D are often using CGM alone when bolusing insulin, obtaining data on the safety and efficacy of this approach will be important. If indeed insulin dosing decisions are proven to be safe and effective using CGM alone (without BGM confirmation) compared to CGM with BGM confirmations, this study would also pave the way for a new standard diabetes management protocol and therapy that would not require eight BGM measurements (i.e. finger sticks) a day and ease the burden of managing type 1 diabetes. For this study, participants will be randomly assigned with 2:1 probability to the CGM Only and CGM+BGM groups, respectively. Prior to randomization, the study will be preceded by a run-in period of up to 10 weeks to collect blinded baseline CGM data, to train the participants on CGM use, to assess compliance with CGM use, and to initiate standard CGM use. During the standard CGM use run-in phase, visits will occur after 2, 4 and 8 weeks, with phone calls at 1, 3, and 6 weeks. Current CGM users may be eligible to skip part of the run-in phase. Participants successfully completing the run-in phase will be randomized. Both groups will use CGM devices and BGM. The CGM device to be used in the study is the Dexcom G4 Platinum Continuous Glucose Monitoring System with modified algorithm. The CGM+BGM group will be instructed to measure the blood glucose whenever a diabetes management decision is made. The CGM Only group will be instructed to only measure the blood glucose (other than for calibration) with a standard BGM meter in certain circumstances and will use a blinded BGM meter at times when a standard BGM measurement is not done. Following randomization, there will be a phone contact during the first week (4 to 8 days following randomization) to address any questions the participant has about the protocol. Follow up visits will occur at 3, 6, 13, 19 and 26 weeks.
Age
18–any
Sex
ALL
Healthy volunteers
Not accepted
