Loading clinical trials...
Loading clinical trials...
A Randomized, Cross-over, Clinical Trial to Assess the Prevention of Ovulation Achieved by Single Intra-vaginal Administration of 0.75 mg Levonorgestrel (LNG) Gel (Levogel) as Compared to 1.5 mg Oral LNG
It has been proposed that levonorgestrel (LNG) in a vaginal gel could be used as an 'on demand' contraceptive when used before coitus. Levonorgestrel was selected as it is a component of many approved oral contraceptive pills and also it is the active agent in Plan B, an FDA-approved regimen for emergency contraception (EC). In previous studies it was demonstrated that an LNG vaginal gel was absorbed and was effective in preventing follicular rupture. The overall proportion of cycles with lack of follicular rupture within 5 days of LNG administration or with ovulatory dysfunction (follicle rupture preceded by an inadequate LH surge) was 96% for LNG gel and 39% in the inert gel cycles (control group).
A dose of 0.75mg of LNG in a vaginal gel was shown to prevent ovulation in a higher percentage than what has been observed with oral LNG at the approved doses for EC of 1.5mg. Results from a study with a1.5 mg LNG oral dose or a single 0 ,75mg dose demonstrated that the proportion of cycles without follicle rupture or ovulatory dysfunction within 5 days was 86% and 79% respectively (Croxatto et al, 2004) , whereas lack of follicular rupture or the presencr of ovulatory dsyfunction was 96% with administration of a LNG gel formulation. In the group of women with follicle size ≥18mm the gel induced 50% ovulation suppression while oral LNG in previous studies blocked only 16% of ovulation in the same follicle size group . These encouraging results could be explained by higher bioavailability of LNG when administered vaginally. This comparison was made using historical data from another study; therefore this study will compare vaginal administration of LNG to oral in a direct cross-over comparative study. LNG is known to affect the cervical mucus by making it hostile to sperm penetration and its effect may appear after only a few hours following oral administration (Kesseru, 1984; Brache, unpublished observations). Application of LNG gel in the vagina close to the cervical os may exert a direct effect on the cervical mucus. The potential local action of LNG on the cervical mucus may be another important mechanism by which protection is conferred to women who do not experience ovulation suppression. An "on demand" precoital contraceptive is an attractive alternative to the post-coital emergency contraception currently available, especially due to the higher efficacy of this route of administration on ovulation suppression as compared with oral tablets of LNG. Should the present study confirm the superiority of vaginal administration of half the dose of the oral dose of LNG approved for emergency contraception, further development of that formulation and method would be warranted.
Age
21 - 39 years
Sex
FEMALE
Healthy Volunteers
Yes
Instituto Chileno de Medicina Reproductiva
José Victorino Lastarria 29, Santiago Metropolitan, Chile
Profamilia
Socorro Sanchez No. 160, Santo Domingo Province, Dominican Republic
Start Date
January 1, 2011
Primary Completion Date
November 1, 2014
Completion Date
November 1, 2014
Last Updated
August 15, 2017
20
ACTUAL participants
Levonorgestrel (LNG) gel (Levogel) and oral LNG (Plan B)
DRUG
Lead Sponsor
Population Council
NCT06672016
NCT07222228
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT01178125