Loading clinical trials...
Loading clinical trials...
Showing 1-20 of 64 trials
NCT07254806
This is a Phase III, randomized, double-blinded, Sham-controlled, multi-center study in subjects with single-level, symptomatic lumbar (L3- S1) intervertebral disc degeneration. The study will have a 52-week primary period followed by 52 week Follow-up Period (total of 104 weeks). The study protocol will be approved by the Institutional Review Board (IRB) or Independent Ethics Committee (IEC), and the study will be conducted in accordance with Good Clinical Practice (GCP). All subjects will provide written informed consent prior to Screening. Approximately 162 subjects will be enrolled in the study. Up to 45 days prior to treatment, subjects will be screened for study inclusion, which includes obtaining baseline MRI and X-ray imaging. Imaging results for subjects initially eligible for study participation will be sent to a central imaging vendor for review and confirmation of eligibility, including the number of levels with degeneration. Subjects meeting all inclusion/exclusion criteria will be assigned to the corresponding treatment arm group and subsequently randomized to IDCT or Sham. Randomization will occur approximately 7 to 14 days prior to the scheduled treatment administration date. Overall, 162 subjects will be enrolled and randomized to IDCT or Sham in a 2:1 ratio. * IDCT (n=108) * Sham (n=54)
NCT05508360
This study will be a prospective, open-label, multi-center study including 72 patients that will collect additional safety and efficacy data for the Spinal Stabilization Technologies PerQdisc Nucleus Replacement System.
NCT05037968
This is a phase IV post-marketing study for MagnetOs Flex Matrix. MagnetOs Flex Matrix is a synthetic bone graft extender product that is routinely used by surgeons as a treatment for patients with degenerative disc disease and undergoing spinal fusion surgery. In this study, MagnetOs Flex Matrix will be used according to the latest U.S. Instructions For Use, specifically as a bone graft extender mixed with autograft in a 1:1 vol.% in the posterolateral spine. Trinity Elite will also be used according to its latest IFU approved in the US. Specifically, this cellular based allograft is an allograft intended for the treatment of musculoskeletal defects.
NCT05029726
Opioid overuse is a widespread public health crisis in the United States with increasing rates of addiction and overdose deaths from prescription opioids. Reducing the need for opiate analgesics in the post-operative setting has become a high priority in minimizing long-term opioid use in surgical patients. This study will serve to demonstrate the efficacy of the addition of regional analgesic techniques in reducing post-operative opioid requirements in patients undergoing common lumbar spinal surgical procedures.
NCT06011551
A multi-center, prospective, dual arm, randomized, controlled pivotal study to evaluate the safety and effectiveness of the ReGelTec HYDRAFIL™ System.
NCT04416321
The purpose of this trial is to collect clinical outcomes including radiographic and CT outcomes in patients who undergo spinal fusion using the Keos Lumbar Interbody Fusion Device.
NCT07363759
This study aimed to investigate a novel technique for intraoperative quantitative and qualitative feedback during discectomy and endplate preparation in TLIF.
NCT06383949
This is a real world data collection observational study at a single site. There are both prospective and retrospective cohorts. The study will examine the safety and effectiveness of the Synergy cervical disc system in patients with degenerative cervical disc disease.
NCT00947583
This study is being conducted to determine the percentage of patients with solid spinal fusions after being treated with Osteocel Plus in a TLIF procedure. Due to the unique processing conditions, Osteocel Plus retains a high concentration of stem cells in conjunction with the allograft bone matrix, so it is hypothesized that the fusion rate with Osteocel Plus will be comparable to published data for autograft. The Osteocel product family has already been used in approximately 15,000 cases worldwide.
NCT04689880
The primary objective of this study is to evaluate the safety and performance of the NuVasive XLIF Decade Plate System as measured by patient-reported outcomes (PROs), radiographic outcomes, and reported complications.
NCT04418830
The objective of this study is to evaluate the safety and performance of NuVasive interbody implants when used during thoracic and/or lumbar spine surgery as measured by reported complications, radiographic outcomes, and patient-reported outcomes. This study is being undertaken to identify possible residual risks and to clarify mid- to long-term clinical performance that may affect the benefit/risk ratios of these interbody implants.
NCT04469231
A multicenter, prospective, non-randomized, historically controlled study. Demonstrate the Synergy Disc is at least as safe and effective as conventional anterior cervical discectomy and fusion (ACDF) to treat cervical degenerative disc disease (DDD) in subjects who are symptomatic at only one level from C3 to C7 that are unresponsive to conservative management. Patients will be evaluated preoperatively, at the time of surgery, and at 6 weeks, 3, 6, 12, and 24 months after surgery. Follow-up will continue annually until the last patient reaches 24-month follow-up. The primary analysis will occur at 24 months.
NCT05880823
This is a real world data collection observational study at a single site. There are both prospective and retrospective cohorts. The study will examine the safety and effectiveness of the Synergy cervical disc system in patients with degenerative cervical disc disease.
NCT06000319
The aim of this study is to evaluate the effectiveness and safety of Natural Matrix Protein™ (NMP™) fibers when used in cervical or lumbar interbody fusion in patients with degenerative disc disease (DDD), spinal stenosis, spondylolisthesis undergoing cervical or lumbar interbody spine fusion at no more than 3 adjacent levels.
NCT04229017
This study will evaluate the safety and effectiveness of a device called "Posterior Cervical Stabilization System or PCSS" when used along with posterior cervical fusion (PCF) in combination with anterior cervical discectomy and fusion (ACDF) in the treatment of multi-level cervical degenerative disease.
NCT05536453
The objective of this retrospective study is an investigational clinical follow-up, of patients treated with interbody fusion devices (IBFD), both expandable (EXP) and static (STC), according to their intended use and cleared labeling to understand IBFD design and technique characteristics that affect occurrence rates of subsidence. Patients treated with IBFD's (both EXP and STC) according to their intended use and cleared labeling 1. EXP IBFD's that expand in width and height demonstrate reduced occurrence of subsidence post-operatively when compared to EXP IBFD's that expand in height only and STC IBFD's. 2. EXP IBFD's that are comprised of multi-material composition with Polyetheretherketone (PEEK) endplate contacting surfaces demonstrate reduced occurrence of subsidence on post-operative radiographs when compared to EXP and STC IBFD's that are primarily comprised of Ti with Ti endplate contacting surfaces. 3. achieve radiographic fusion at a rate consistent with the state-of-the-art 4. achieve significant improvements in pain and function compared to baseline 5. experience adverse events at a frequency comparable to reported rates for TLIF or PLIF surgery 6. not demonstrate any intraoperative complications during the implant process 7. operative approach does not correlate with increased rates of subsidence
NCT03438747
The aim of this trial is to evaluate if P-15L bone graft (investigational device) is not inferior in effectiveness and safety to local autologous bone (and allograft where necessary) as an extender (control device) when applied in instrumented transforaminal lumbar interbody fusion (TLIF) in subjects with degenerative disc disease (DDD). In addition to the general overall objective, a sub-group analysis will be performed on the high-risk subject population (tobacco use, obesity, diabetes), as previous studies have shown negative effects of smoking, obesity and diabetes on fusion and bone healing, increased peri/postoperative complications, and lower patient-reported outcome scores.
NCT04204135
The purpose of this study is to assess the course of hip weakness after LLIF or ALIF procedures. These outcomes include measures of hip strength using a dynamometer, which is a device used to measure muscle strength. While it is known that people experience temporary hip and leg weakness after an LLIF or ALIF, the exact timing of when hip and leg strength is regained after an LLIF or ALIF is not known.
NCT05944081
The purpose of this study is to collect clinical and radiological mid-term (min. 1 year) data on the ArcadiusXP L® lumbar stand-alone cage in a post-market clinical follow-up study (PMCF) limited to 60 patients.
NCT07127380
Background Degenerative disc disease (DDD) is the leading cause of lower back pain and disability, which prevalence increasing with age. When conservative treatment fails, surgical methods of spinal fusion are employed. Minimally invasive techniques, including minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) and midline lumbar interbody fusion (MIDLIF), have well-documented advantages over traditional open transforaminal interbody fusion (open-TLIF). However, data comparing these two minimally invasive methods in treating DDD are minimal and sometimes contradictory. I am running a few minutes late; my previous meeting is running over. Methods This is a prospective, randomized, partially blinded, two-arm trial aiming to compare the outcomes, complications, and treatment costs of MIS-TLIF and MIDLIF in patients with discogenic low back pain. A total of 100 adult patients with lumbosacral spine pain and radicular symptoms, unresponsive to conservative treatment for over one year, will be enrolled. Patients will be randomized (1:1) into two arms: MIS-TLIF (control, n=50) and MIDLIF (intervention, n=50), with a 12-month follow-up. Inclusion criteria include age ≥18 years and discopathy at one or two levels requiring interbody stabilization. Exclusion criteria include multilevel pathology, spinal deformities, and pain causes other than degenerative disease. Primary endpoints assess pain (VAS, NRS scales), disability (COMI, ODI questionnaires), and quality of life (EQ-5D-5L questionnaire) at 1, 3, 6, and 12 months post-surgery. Secondary endpoints include complication rates (nerve root damage, infections), costs (hospitalization, implants), length of hospital stay, procedure duration, blood loss, morphometric parameters (intervertebral space height), and adjacent segment disease based on imaging studies (MRI, CT, X-ray). Data analysis uses parametric/non-parametric tests (e.g., t-test, Mann-Whitney) in the R software. The trial adheres to the Helsinki Declaration, with ethics approval (no. 112/2024). Discussion Data on the comparison of MIDLIF and MIS-TLIF in treating DDD are minimal and inconsistent. Some reports have advantaged MIDLIF in shorter operative time, decreased intraoperative blood loss, and reduced hospital stays, while others favor MIS-TLIF. This trial addresses these gaps by providing high-quality evidence on clinical superiority, cost-effectiveness, and long-term outcomes compering MIDLIF and MIS-TLIF. There is a high need for a high-quality, prospective study to examine this problem.