Loading clinical trials...
Loading clinical trials...
Showing 1-10 of 10 trials
NCT01737567
Removal of colorectal adenomas prevents the occurence of colorectal cancers. The use of chromo-endoscopy has been shown to improve the detection of flat adenomas. Narrow band imaging enables endoscopists to accurately describe the pit pattern of adenomas. By comparing White Light Endoscopy and Bright Narrow Band Imaging it will show if there is any comparable advantage to using one or the other for lesion detection and assessment.
NCT02957058
To prospectively validate the SERT (Sydney EMR Recurrence Tool) scoring system for adenoma recurrence rates around the endoscopic mucosal resection (EMR) scar after wide field-EMR with thermal treatment applied to the defect margin. The primary aim of the study will be to ensure the safety of this approach and there will be constant monitoring to ensure that this is the case.
NCT06217250
This randomized, multi-center trial aims to evaluate the advantages of underwater cold endoscopic mucosal resection technique (CS-EMR) in comparison to the conventional endoscopic mucosal resection technique (EMR) for laterally spreading colorectal lesions exceeding 20 mm in size. More precisely, our hypothesis posits that underwater cold EMR is non-inferior to conventional EMR in terms of recurrence rates, resection completeness and safety.
NCT05836064
It is estimated that about 20% of colonoscopies have inadequate preparation. (5) This is associated with lengthy procedures and less detection of adenomas, reduces the screening intervals, and increases the costs and risks of complications. Several strategies have been proposed to improve the quality of bowel preparation. Mobile healthcare Apps have been developed to increase adherence to bowel preparation agents, improving the quality of bowel preparation. However, adherence to mobile healthcare Apps is also a quality criterion and a pending problem to solve with this new technology. GastroBot is a new technology based on artificial intelligence that allows, through a software bot, to carry out a personalized follow-up of the patient's bowel cleansing, advising the patient to overcome contingencies that arise with the preparation, which in other circumstances could lead to the failure of it. The primary aim of this study is to determine the improvement in bowel preparation after GastroBot assistance compared with the traditional explanation. As a secondary aim, this study also pursues to determine adenoma and polyp detection rates (ADR and PDR, respectively), bowel preparation agents' tolerance, and GastroBot functionality.
NCT03832322
This was an observational study comparing consecutive group of WE and CO2 insufflation in terms of right and proximal colon AMR by tandem colonoscopy.
NCT03954561
Loop formation is the most frequent cause of cecal intubation failure during colonoscopy. To reduce the loop formation, external abdominal pressure is widely used and proved to be helpful. Properly applied pressure can also decrease patients discomfort and shorten the cecal intubation time. The loop formation during water exchange is less severe as compared with during air insufflation and can be reduced quite readily. Traditionally an assistant is not asked to administer abdominal compression until the endoscopist has struggled for some time and failed to reduce the loops by withdrawal. The colonoscopist can administer the abdominal compression whenever the scope is not advancing smoothly, probably in the early stage of loop formation. We test the hypothesis that colonoscopist administered abdominal compression to remove loops in their early stage of formation hastens cecal intubation. A total of 120patients will be randomized in a 1:1 ratio (n=60 per group). When the tip of the scope doesn't advance or paradoxical movements occur, loop reduction by withdrawal of the scope will be implemented. If looping persists, abdominal compression will be applied. In the endoscopist-administered abdominal compression (endoscopist) group, the colonoscopist will apply the compression with his right hand and counter the pressure by pushing the back of the patient with his left forearm with the colonoscope in his left hand. The compression will be administered at left lower quadrant when the scope is in the sigmoid colon and at left lower quadrant and upper abdomen, respectively, when the scope tip reaches the transverse or ascending colon. If the formation of loop cannot be overcome, an assistant will apply the abdominal compression instead. In the assistant-administered abdominal compression (assistant) group, an endoscopic assistant will apply abdominal compression when a loop is formed. The assistant will apply the compression at the left lower quadrant initially, but quickly shift to other parts as needed depending on the tip location of colonoscope. If manual compressions fail, then the patients' position will be changed.
NCT04512729
Colorectal carcinoma (CRC) is the third most common cancer in male and female worldwide. In India, it is the fourth most common cause of cancer in males and third most common cancer in female. Age, smoking, colonic adenomatous polyp, family history are traditional risk factor for CRC. The vast majority of CRC results from malignant transformation from adenoma, which is called as adenoma carcinoma sequence. These adenomatous polyps grows slowly over many years and malignant transformation eventually occurs over 10 years. So, the early detection and removal of polyp at early stage should benefit in preventing CRC.
NCT03783156
Colonoscopy is the technique of choice for the diagnosis and prevention of colorectal cancer (CRC). The identification and extirpation of adenomas decreases the incidence of CRC by up to 76%. More than 70% of the excised lesions are less than 10 mm. There is controversy about the technique to be used (resection with cold vs hot snare) in lesions of 5-9mm. Both use a polypectomy snare. The cold snare cuts by friction, while the hot snare uses electrical current. We propose a multicenter randomized clinical trial comparing both endoscopic techniques. At least 394 injuries per group will be included, randomizing patients to whom a diagnostic colonoscopy is requested for symptoms, screening or revision protocols. Randomization will be performed stratified by center. The primary objective is the proportion of incomplete polypectomies, which will be analyzed centrally from random biopsies of the edges of the lesion. As secondary objectives, we will compare the proportion of immediate and delayed hemorrhagic complications, the evolution of postprocedural abdominal pain and the factors associated with incomplete excision in each group and the factors associated with a failed cold polypectomy. The analysis of the primary objective will be carried out by means of the z test of homogeneity without using the correction of Yates, estimating the confidence interval of the difference between both groups. The analysis will be carried out by intention to treat and per protocol.
NCT02051465
Colorectal cancer accounted for 142,570 new cancer cases and 51,370 cancer deaths in USA in 2010 and worldwide has become the third most common cancer and second leading cause of cancer related deaths. Colonic adenomatous polyps are known precursors of colorectal cancer and endoscopic removal of the polyps prevents development of colon cancer. Removal of such large polyps requires special endoscopic techniques-endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD), which are more technically difficult to perform, labor intensive, time consuming and carries higher risks of complications (bleeding, perforations, etc.). The purpose of this study is to determine the effectiveness and safety of the LumenR Retractor in performing EMR and ESD. It is hypothesized that the use of this modified colonic overtube will simplify colonoscopic removal of difficult polyps, decrease the time needed to complete the procedure and decrease the rate of complications post endoscopic removal of large and flat colonic.
NCT01422577
Early detection of colo-rectal adenoma using colonoscopy can prevent occurrence of colon cancers. While colonoscopy is a standard technique, it can miss early cancers. To improve the detection rate, Narrow Band Imaging (NBI) was introduced in 2006. It has been shown to compare favorably with chromo-endoscopy in the sensitivity and specificity in the diagnosis of malignant colo-rectal neoplasms. The major drawback of NBI is that images become dark in the presence of blood and fecal matters. The bright-NBI is a prototype imaging technology that enables endoscopists to obtain better images in suboptimal conditions. The study proposes to compare the performance of colonoscopy using either white light or bright NBI in subjects undergoing screening colonoscopy in search for colon adenomas. Purpose To determine that bright -NBI is superior to WLE in detecting colorectal adenomas in average risk subjects undergoing screening colonoscopy.