Loading clinical trials...
Loading clinical trials...
It is a cross-sectional, randomized, and single-center study with a duration of 6 months. The study will follow the STROBE guidelines for cross-sectional studies and CONSORT 2024. The main objective is to evaluate the validity and reliability of two devices in measuring grip strength and muscle fatigability in community-dwelling older adults.The study will include community-dwelling older adults of both sexes over 60 years of age.
Design: It is a cross-sectional, randomized, and single-center study with a duration of 6 months. The study will follow the STROBE guidelines for cross-sectional studies and CONSORT 2024. The main objective is to evaluate the validity and reliability of the Device 1 and Device 2 devices in measuring grip strength and muscle fatigability in community-dwelling older adults. It will be carried out in two stages: In a first moment the criterion and interobserver validity will be assessed and in a second moment the intraobserver validity. Participants will be randomly assigned to one of the 6 arms to follow different orders of the devices (Device 1, Device 2 or Jamar). Population: community-dwelling older adults of both sexes over 60 years of age. Procedures: The investigators will schedule each participant for the initial assessment day. Using a table of random numbers, they will be assigned one of the arms. All participants have previously read, signed and given their written informed consent. An interview will be conducted in which age, sex and medication will be collected; an anthropometric and functional assessment will be performed. The functional tests include the 30-second squat test and grip strength tests using the Jamar, Device 1 and Device 2. Three repetitions will be performed with each device, allowing 30 seconds between repetitions and 3 to 5 minutes between devices. After 20 minutes the test will be repeated again on the devices for interobserver validation. 5 to 10 days later, tester 1 will repeat the grip test with the same effort to assess intraobserver reliability. Sample size: Similar studies validating grip strength devices compared to the Jamar showed an excellent correlation (ICC \> 0.90). With an estimated ICC of 0.90 ± 0.05 and an alpha risk of 5%, 348 participants are required for the training study. Variables: Sociodemographic (age, sex, hand dominance, number of medication types), anthropometric (height, weight, BMI and SMI), strength and fatigability (total number of repetitions in 30sCS, maximal grip strength (HGS), fatigue resistance (FR) and grip work (GW)) and device preference. Statistical analysis: Maximal strength and fatigability will be analyzed by means of means, standard deviations and statistical tests. Concordance between devices will be assessed using the Kappa coefficient and the Bland-Altman concordance index. ROC curves will be used to determine sensitivity and specificity, and data will be analyzed by gender. Results will be considered statistically significant if p \< 0.05, and IBM SPSS Statistics v28.0 will be used for analysis.
Age
65 - No limit years
Sex
ALL
Healthy Volunteers
Yes
University of Salamanca
Salamanca, Salamanca, Spain
Start Date
December 16, 2024
Primary Completion Date
March 31, 2025
Completion Date
April 15, 2025
Last Updated
December 18, 2025
413
ACTUAL participants
Validation and reliability
DIAGNOSTIC_TEST
Lead Sponsor
University of Salamanca
NCT05884138
NCT07469761
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT06950125