Loading clinical trials...
Loading clinical trials...
Validation of Apnea Test Conducted Using High-flow Oxygen Therapy in Patients With Clinical Brain Death
Brain death is a clinical and paraclinical diagnosis established in a known etiological context. It involves the irreversible destruction of cerebral functions in a beating-heart individual. In the context of organ and tissue donation from a critically ill patient, the clinical diagnosis of brain death is confirmed through a mandatory apnea test. This test is conducted by disconnecting the patient from the ventilator for a duration of 8 to 10 minutes. The test is considered validated when there is no spontaneous respiratory movement and the presence of hypercapnia. Hypercapnia is defined as a PaCO2 (carbon dioxide partial pressure) greater than 60 mmHg or an increase of more than 20 mmHg compared to the pre-ventilator disconnection capnia. These thresholds are meant to provide a strong stimulus to the respiratory centers, objectively confirming the absence of spontaneous ventilation. In practice, the apnea test is performed under CPAP (Continuous Positive Airway Pressure) or by administering oxygen at 6-10L/min through the endotracheal tube. High-flow oxygenation could be a simple alternative for the apnea test during the validation of the clinical diagnosis of brain death while reducing the risk of lung derecruitment and compromising organ viability and/or lung donation. However, due to the high gas flow used (60 L/min), high-flow oxygenation can lead to a "washout" effect in the anatomical dead space, which may lower the carbon dioxide partial pressure. Consequently, even in a patient in a state of brain death, where spontaneous ventilation is absent by definition, it is not certain that the carbon dioxide partial pressure will increase to the threshold of 60 mmHg or more than 20 mmHg in 10 minutes during an apnea test conducted with high-flow oxygenation. The purpose of this study is, therefore, to examine the feasibility of clinically diagnosing brain death through an apnea test performed with high-flow oxygenation. To determine whether the validation criterion which involves observing an arterial capnia \> 60 mmHg or an increase \> 20 mmHg (compared to the capnia at the beginning of the test) after 10 minutes can be achieved during an apnea test conducted under high-flow oxygen therapy in patients with clinically confirmed brain death by standard apnea test (under standard oxygen therapy)
The protocol is based on performing two consecutive apnea tests on a patient in clinical brain death in intensive care unit. The first apnea test will be conducted under standard oxygen therapy and confirms clinical brain death (standard procedure). The second apnea test (for the study) will be conducted under high-flow oxygen therapy. Only patients whose apnea test is initially validated under standard oxygen therapy will have the second apnea test under high-flow oxygen therapy. After a standardized preoxygenation, the 1st apnea test will be performed under standard oxygen therapy through the endotracheal tube (flow at 8L/min) for 10 minutes. An arterial blood gas sampling will be sampled every 2 minutes during the1st apnea test. The confirmation of clinical brain death by validating the apnea test under standard oxygen therapy will be done if the following two conditions are met: 1) absence of a spontaneous respiratory movements AND 2) an arterial capnia \> 60 mmHg or an increase \> 20 mmHg (compared to the capnia at the end of preoxygenation). Then the patient will be reconnected to the ventilator for 15 minutes. A second standardized preoxygenation will be performed before the 2nd apnea test. The second apnea test will be performed under high-flow oxygen therapy through the endotracheal tube (flow at 50L/min, FiO2 100%) for 10 minutes. An arterial blood gas sampling will be sampled every 2 minutes during the1st apnea test. Then the patient will be reconnected to the ventilator with the same settings before the start of the study.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
CHR d'ORLEANS
Orléans, France
Start Date
July 10, 2023
Primary Completion Date
April 7, 2024
Completion Date
April 7, 2024
Last Updated
August 2, 2024
15
ACTUAL participants
Apnea test under high-flow oxygenation
DIAGNOSTIC_TEST
Lead Sponsor
Centre Hospitalier Régional d'Orléans
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT04404972