Accuracy of Detachable String Magnetically Controlled Capsule Endoscopy for Follow-up of Patients With Esophageal Diseases: A Multicenter Study
The purpose of the study is to determine the accuracy of detachable string magnetically controlled capsule endoscopy(DS-MCE) as a follow-up method for patients with previous esophageal diseases.
Esophagogastroduodenoscopy (EGD) is recognized as the gold standard for detection and follow-up of esophageal diseases,allowing for direct mucosal visualization and therapeutic intervention. EGD is however an invasive procedure and there is potential for procedure-related complications, such as perforation and bleeding.Esophageal capsule endoscopy(ECE)provides a novel noninvasive approach to visualize the esophagus.The main drawback for the use of ECE is its unreliable transit time which often renders an inadequate visualization of the esophagus.Thus investigators have developed the detachable string magnetically controlled capsule endoscopy(DS-MCE) which can control the movement of the capsule through the string. The ds-MCE system consists of two parts: the magnetically controlled capsule endoscopy (MCE) system and a transparent latex sleeve with a hollow string. The magnetically controlled capsule endoscopy (MCE) system (Ankon Technologies, Shanghai, China) detects focal lesions in the stomach with comparable accuracy with conventional EGD. One end of the hollow string is a transparent thin latex sleeve that can be wrapped on the surface of the capsule, and the other end of the string is connected to the syringe. The capsule, which is partially enclosed within the sleeve, can be actively moved in the esophagus through the control of string. In this case, investigator can examine the entire esophageal mucosa several times under real time views. The capsule then could be detached from the string system through injecting air into the hollow string with the syringe after completing the examination of esophagus. The pilot study of ds-MCE confirmed it was a feasible, safe and well-tolerated method for completely viewing esophagus and stomach, without the need for sedation. Besides, the 8-10h battery life of the ds-MCE enables complete examination of the small bowel, which provides the possibility for screening pathological changes in the entire gastrointestinal tract. This study is a prospective, multi-centered, diagnostic accuracy study. The primary outcome is the diagnostic accuracy of ds-MCE in identifying esophageal diseases. Second outcomes include the visualization and cleanliness of Z-line, safety and patient satisfaction of DS-MCE.
Age
18 - 75 years
Sex
ALL
Healthy Volunteers
No
Ruijin Hospital
Shanghai, China
Shanghai Changhai Hospital
Shanghai, China
Shanghai General Hospital
Shanghai, China
Shanghai Sixth People's Hospital
Shanghai, China
Xuhui District Central Hospital
Shanghai, China
Yangpu District Central Hospital
Shanghai, China
Zhongshan Hospital
Shanghai, China
Start Date
July 15, 2019
Primary Completion Date
September 15, 2022
Completion Date
September 15, 2022
Last Updated
July 21, 2022
310
ESTIMATED participants
ds-MCE and EGD
DIAGNOSTIC_TEST
Lead Sponsor
Changhai Hospital
Collaborators
NCT06315179
NCT05624099
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions