Loading clinical trials...
Loading clinical trials...
Evaluation of Wearable Multi-modality Sensors for Monitoring Vital Signs
The purpose of this study is to investigate the safe wearability and basic functions of the multi-modality sensors fabricated in the PI lab.
Members of this research team have developed innovative, wearable devices capable of being comfortably and continuously worn while recording diverse physiologic measurements. The purpose of this study is to validate the safe wearability and basic functions of the novel biocompatible electronic sensor that will allow continuous, non-invasive physiological measurements. This study aims to obtain preliminary data on the safety and functional aspects of the developed devices and compare it to approved medical equipments (including Abbott Medquip Oximeter, Omron blood pressure monitor, and Vicorder device for pulse wave velocity), which will pave the way for future study that focuses certain disease model. Participants will be randomly assigned to Condition A, and wear the devices before and after exercise for 15 minutes each time, or Condition B and wear the devices for 2 hours continuously. During their 1-hour or 2.5-hour lab visit, study participants will wear the biocompatible electronic sensors and three approved medical devices during a slow deep breath, before and after a 6-minute brisk walk, or for an extended period of time (2 hours). Participants will return to the lab for two brief visits, 48 and 96 hours after the device wearing, to determine if any suspected adverse events related to study procedures or devices emerged after they left the research site. For the future study, we will plan to 1) optimize the devices for use in patients needing FiO2 weaning, 2) demonstrate the reliability, and accuracy of these devices for continuous physiological measurements, including but not limited to blood pressure, heart rate (HR), cerebral blood flow, temperature, glucose concentration, and respiratory rate, and 3) demonstrate these devices are preferred by patients to current measurement tools. Once validated, such sensors could fundamentally change the way blood flow, blood pressure, or related parameters are monitored for patients, eliminating risks associated with invasive monitoring, allowing continuous, real-time detection of clinically meaningful changes in the patients, advancing knowledge of hormonal signatures and physiological signals preceding clinically meaningful events.
Age
18 - 99 years
Sex
ALL
Healthy Volunteers
Yes
Kenan Laboratories at the University of North Carolina at Chapel Hill
Chapel Hill, North Carolina, United States
Start Date
January 9, 2024
Primary Completion Date
November 1, 2025
Completion Date
November 1, 2025
Last Updated
September 22, 2025
22
ESTIMATED participants
Multi-modality Noninvasive Biosensor
DEVICE
Oximeter
DEVICE
Portable Blood Pressure Monitor
DEVICE
Vicorder Pulse Wave Velocity Monitor
DEVICE
Lead Sponsor
University of North Carolina, Chapel Hill
Collaborators
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.