Pressure-Volume (PV) Measurements for Evaluating the Changes in the Ventricular Preload and Autonomic Nervous System Using BackBeat Medical Cardiac Neuromodulation Therapy (CNT) Signals in an Acute Study
This investigation will evaluate the effect of RV pacing lead position on cardiac function and the modulation of the autonomic nervous system with Cardiac Neuromodulation Therapy (CNT) pacing signals. The study will be performed acutely prior to a pacemaker implant.
Subjects indicated for a dual chamber pacemaker implant or replacement who are not 100% dependent on right ventricular pacing may be eligible to participate in the study. This investigation will evaluate the effect of RV pacing lead position on cardiac function and the modulation of the autonomic nervous system using Cardiac Neuromodulation Therapy (CNT) pacing signals at different positions of the RV pacing lead. A standard conductance catheter will be introduced through the femoral artery and advanced into the left ventricle to measure cardiac volumes and pressure. Arterial blood pressure will be measured from the other femoral artery with an additional sheath. The Moderato® IPG will be used to generate Cardiac Neuromodulation Therapy (CNT) signals and deliver them to the patient through the cable and leads. A range of CNT signal parameters will be used to assess the effect on sympathetic activity at different positions of the RV pacing lead. Ventricular pressure and volume readings from the conductance catheter and arterial pressure readings will be recorded and analyzed to assess the effect of CNT signals on cardiac function, sympathetic activity and blood pressure. The effects of CNT signal over a range of parameter settings will be studied for the different RV lead positions.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
Na Homolce Hospital
Prague, Czechia
Start Date
August 7, 2020
Primary Completion Date
March 31, 2023
Completion Date
July 31, 2023
Last Updated
September 19, 2022
30
ESTIMATED participants
Moderato IPG's CNT pacing signals
DEVICE
CD Leycom Pressure/Volume Combination Catheters
DEVICE
Lead Sponsor
BackBeat Medical Inc
Collaborators
NCT07221682
NCT03008291
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT07290595