A Retrospective Radiological Analysis of the Mechanical Performance of Different Locking Plates in Distal Femoral Fractures
In order to assess the rate and mode of failure cases observed in patients with distal femur fractures treated with a distal femur plates, anonymized radiographs from those patients will be collected retrospectively. All available images will reviewed by an expert review board in regards to fracture classification, implant and surgery details, quality of initial reduction and plate positioning as well as the occurrence of mechanical complications and the outcome in terms of fracture healing (if available). Additionally, age and gender as basic demographical data will be collected in a de-identified way..
Severely comminuted distal femur fractures can be challenging injuries and usually require surgical treatment with lateral distal plate osteosynthesis. Anatomically pre-contoured locking plates are commonly used. In 2012, the 4.5mm VA-LCP Curved Condylar Plate for distal femur fractures (VA-LCP DF, Synthes) was introduced offering the option of axis variation of the locking screws. Recently, a report highlighted cases of implant failure with this implant, cautioning practicing surgeons against the use of this implant in certain type of AO/OTA fracture and dislocation classification 33 fractures (AO/OTA classification). Based on this report, the current study was designed to perform a retrospective in-depth radiological analysis of all cases distal femur fractures of 4 participating sites in which the VA-LCP DF, the LCP Distal Femur Plate (LCP DF, Synthes) or the 'less invasive stabilization system' for distal femur fractures (LISS DF, Synthes) were used for fracture stabilization. The radiological in-depth analysis will be done by an expert review board with the aim to identify potential causes and risk factors for the failure cases among all cases collected. This evaluation will contribute to a better understanding of the mechanical performance of distal femur fracture plates and the causes and risk factors for failures.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
University of California
Sacramento, California, United States
Houston, Texas, United States
Inova Orthopedics
Fairfax, Virginia, United States
Kantonsspital Liestal
Liestal, Basel-Landschaft, Switzerland
Kantonsspital Graubünden
Chur, Kanton Graubünden, Switzerland
Start Date
January 1, 2012
Primary Completion Date
April 24, 2025
Completion Date
April 24, 2025
Last Updated
September 16, 2025
100
ESTIMATED participants
Distal femur plates
DEVICE
Lead Sponsor
AO Innovation Translation Center
NCT07280169
NCT05805774
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT06078371