Accuracy of Cone Beam Computed Tomography in Measuring of Mandibular Pig Soft Tissue Thickness Using a Radiopaque Material in Comparesion With Real Measurement.Diagnostic Study
accuracy of CBCT in measuring soft tissue thickness by using a radiopaque material as the real finding and measurements on pig jaws
* Pig jaws will be included in this study. * Soft tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken. * A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT). * After that, flap were elevated, and actual thickness of soft-tissue (actual thickness, AT) was measured. The Analytical phase: * In order to assess soft tissue thickness and bone levels an electronic digital caliper (Shenhan Measuring Tools Co., LTD, Shanghai) will used for measuring the transgingival probing thickness on the pig jaws. * A graduated Naber's probe will be used for measuring the transgingival probing thickness. Soft tissue thickness measurements: * Intra-observer variability was tested under the supervision of the director. * For the measurement of radiographic thickness (RT), wet soft tissue surfaces were covered with barium sulfate powder (SoloTop; Taejoon, Seoul, Korea), a radiopaque material used as a contrast medium. * A probes and rubber stop were used for the measurement of transgingival probing thickness (TPT). * A rubber stop was placed in contact with the surface to facilitate the measurement of tissue thickness, and then TPT was measured with digital calipers. All measurements were rounded to the nearest 0.01 mm. * For the measurement of actual thickness (AT), an incision was made onto each marked area. After flap elevation, actual soft tissue thickness was measured using the same method that was used for TPT. Radiographic examination * The pig jaws will then be imaged with CBCT. * CBCT scanning will be performed using a PROMAX R 3DMid CBCT device (Planmeca Oy, Helsinki, Finland) with scanning protocol 90 kVp, 8 mA and 13.58 seconds exposure time with a single 360 degree rotation ROMEXIS software. The jawes will be placed on the horizontal plate of the device. The midline and mandibular position will be adjusted using the laser guide
Age
All ages
Sex
ALL
Healthy Volunteers
No
Mahinaz Reda Hassan
Cairo, Giza-elharam, Egypt
Start Date
April 20, 2019
Primary Completion Date
September 30, 2021
Completion Date
December 9, 2021
Last Updated
August 20, 2021
15
ESTIMATED participants
CBCT
RADIATION
Lead Sponsor
Cairo University
NCT05921578
NCT06676358
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions