Loading clinical trials...
Loading clinical trials...
The Novel Use of Point of Care Ultrasound to Predict Resting Energy Expenditure in Critically Ill Patients by Measuring Lean Body Mass Using Musculo-skeletal Ultrasound
The study aims to correlate Lean Body Mass (LBM) Evaluated by Musculoskeletal Ultrasound with Resting Energy Expenditure (REE) measured by Indirect Calorimetry and to generate a predictive equation of REE based on LBM, in addition to identifying other factors that may affect REE such as age, gender, and severity scores.
Caloric needs in critically-ill patients fluctuate significantly over the course of the disease which might expose patients to either malnutrition or overfeeding.Malnutrition is associated with deterioration of lean body mass (LBM), poor wound healing, increased risk of nosocomial infection, and weakened respiratory muscles. On the other hand overfeeding in medically compromised patients can promote lipogenesis, hyperglycemia, and exacerbation of respiratory failure. Many factors may affect the resting energy expenditure (REE) through manipulation of oxygen consumption (VO2). One of the strongest determinants of REE is the LBM. A measurement of muscle mass and changes in muscle mass could thus provide an index of LBM in critically ill patients. At present, computerized tomography, magnetic resonance imaging and dual-energy X-ray absorptiometry (DXA) are widely used as reference methods for evaluating LBM in vivo. However, these methods are impractical in critically ill patients. More practically, ultrasound scanning is a simple, portable, safe, and a low-patient burden technique. Several studies found that the use of ultrasound can be a good estimate to LBM. Indirect calorimetry remains the accepted standard for determining the REE in the critically ill. Indirect calorimetry measures oxygen consumption(VO2) and carbon dioxide excretion (VCO2 ) (both in mL/min), which are used to calculate the respiratory quotient and the resting energy expenditure. Although, the measured LBM has been shown as an important determinant of REE, there was no previous study tested the relationship between estimated LBM by ultrasound-based muscle thickness measurement and REE.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
Faculty of medicine, Cairo University teaching hospitals (Kasr Alainy)
Cairo, Egypt
Start Date
July 1, 2017
Primary Completion Date
July 1, 2018
Completion Date
August 1, 2018
Last Updated
October 4, 2018
40
ACTUAL participants
US Muscle layer thickness (MLT) estimation
DIAGNOSTIC_TEST
REE estimation by indirect calorimetry
DIAGNOSTIC_TEST
Lead Sponsor
Eslam Ayman Mohamed Shawki
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions