Loading clinical trials...
Loading clinical trials...
Evaluation of 'Melody' Paracentesis Device for Ascites Therapy in Patients With Cirrhosis (EMPATHY)
Ascites is the accumulation of fluid inside the abdomen. This can happen when the liver fails due to a substantial amount of scarring (cirrhosis). Patients (pts) must have this fluid drained and as cirrhosis progresses, patients will require drainage of ascites repeatedly on a regular basis, leading to frequent hospitals visits and increased complications. The current drainage device is slow and doesn't always drain completely so pts have to return repeatedly to keep symptoms under control. A new device (called Melody) has been developed and specifically designed for the purpose of draining ascites fluid, which the Investigators expect to drain faster and completely. This study will compare the volume of ascites drained using the new 'Melody' catheter device with that used in standard NHS practice. If the melody catheter device is confirmed as superior to the current device this would improve patient experience (less frequent visits to hospital and increased length of time between visits). With fewer procedures performed per patient, the pressure on the NHS would be greatly reduced in terms of time and costs.
Large volume paracentesis has been established as a treatment for symptomatic ascites and is performed regularly in secondary care hospitals widely across the UK. Lack of a device specifically designed to perform paracentesis means that flow of ascites fluid through the catheter is not optimal leading to incomplete drainage and hence, frequent repeated paracentesis as well as a number of complications. A new 'Melody' catheter device has been designed and developed in collaboration with Mediplus Ltd and NIHR Enteric Bowel function Healthcare Technology Co-operative; specifically designed to improve the performance characteristics of paracentesis procedure. (The 'Melody ascites drainage catheter' including 'sterile ascetic drainage sets' is CE marked for clinical use). In addition, investigators would also like to confirm whether the addition of a pump will improve drainage with this device further. The Investigators propose to carry out a feasibility study, 'EMPATHY', with an aim to compare the performance characteristics of 'Melody' catheter device (with and without addition of 'Andromeda' pump) with the current device. 112 patients with ascites requiring therapeutic paracentesis will be randomised to undergo the procedure using one of the two devices. The volume of ascites drained per session will be compared along with ease of insertion and removal as well as patient experience including all adverse events up to 7 days following the procedure. The outcomes of this feasibility study will inform further refinement of the 'Melody' catheter device as well as a future large multi-centre randomised controlled trial evaluating the cost-effectiveness of the new 'Melody' catheter device in therapeutic paracentesis
Age
18 - 80 years
Sex
ALL
Healthy Volunteers
No
Queen Day Case Unit Nottingham University Hospitals NHS Trust
Nottingham, United Kingdom
Start Date
January 4, 2016
Primary Completion Date
January 10, 2019
Completion Date
January 10, 2019
Last Updated
November 19, 2020
101
ACTUAL participants
standard device
DEVICE
Melody Device
DEVICE
Melody Device with Pump
DEVICE
Lead Sponsor
University of Nottingham
Collaborators
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions