60 post operative patients who are kept intubated overnight \& are spontaneously breathing will be either supplied humidified oxygen Heated Humidifier(HH) or conventional mist nebulizer. Temperature of inspired gas at the Y piece will be measured. Sterile water will be used for HH \& Mist nebuliser. The suctioning of endotracheal tube (ETT) will be done once every 2 hourly by nurse/ doctor/trained personnel and additional suctioning if required.
60 post operative patients who are kept intubated overnight \& are spontaneously breathing will be selected in Tata Memorial Hospital (TMH), Mumbai. 30 patients will be supplied through humidified oxygen using FISHER \& PAYKEL MR 370 Heated Humidifier(HH) \& 30 patients through conventional mist nebulizer. Temperature of inspired gas at the Y piece will be measured as surrogate marker for quality of humidification. Continuous monitoring of temperature will be done using standard monitor. The reusable HH will be subjected to disinfection between patients. Sterile water will be used for HH \& Mist nebuliser. The suctioning of endotracheal tube (ETT) will be done once every 2 hourly by nurse/ doctor/trained personnel. Based on patient's clinical condition , additional suctioning will be done. Frequency of additional suctioning , reason for suctioning will be noted. Information regarding the age, sex, type of surgery of the patient, co-morbidity if any size of ETT, the time of commencement of humidification , duration of use of humidifier, time of extubation, any complication leading to discontinuation of humidifier, frequency of refilling of nebulizer chamber, volume of ETT before intubation etc. will be noted. The amount of Endotracheal tube blockade caused by secretion will be measured immediately following extubation. The volume of Endotracheal tube secretion / amount of blockade will be assessed by the following process- * The bevel end \& Murphy's eye of the Endotracheal tube will be sealed using sterile insulating tape so that it become water tight. The tube will be gradually filled with measured amount of sterile fluid using small volume syringe to increase the accuracy of measurement. The amount of fluid it can hold will be measured \& noted. * The volume of extubated tube will be measured in the similar way. * The measured volume of the Extubated Endotracheal tube will be subtracted from the actual volume of the particular Sized ETT ( measured before intubation). * The result obtained after this subtraction will be the volume of secretion or the volume of ETT that has been blocked.
Age
18 - 80 years
Sex
ALL
Healthy Volunteers
No
Start Date
July 1, 2016
Primary Completion Date
November 1, 2016
Completion Date
January 1, 2017
Last Updated
September 20, 2018
60
ACTUAL participants
heated humidifier
DEVICE
mist humidifier
DEVICE
Lead Sponsor
Tata Memorial Hospital
NCT02296684
NCT04800419
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT04356170