Comparison Of Cytologic Accuracy Of Endobronchial Ultrasound Transbronchial Needle Aspiration Using Needle Suction Versus No Suction
Cytological diagnostic accuracy between endobronchial ultrasonography endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) samples using suction versus samples when no suction is applied.
Endobronchial ultrasound-guided transbronchial needle aspiration which is known as the EBUS procedure is a low risk procedure performed using bronchoscopy to sample chest lesions. A needle is passed through the bronchoscope to biopsy the chest lesion. Every lesion is usually biopsied 3 to 7 times. In most cases the investigators apply a syringe with negative pressure to the needle inserted into lesion for biopsy. In some cases the investigators don't apply any negative pressure. There are no studies to evaluate which one is better, applying syringe suction or no suction. In our study, the investigators are planning to do biopsies with or without suction. Then, the pathology samples will be evaluated for any cytologic difference in making the diagnosis. Any patient undergoing the EBUS procedure for chest biopsies will be eligible. Every lesion will be biopsied at least twice with needle with and without suction. The biopsy samples will be then divided into group A where the investigators applied syringe suction and group B where no syringe suction was applied. There is no risk to the patient in addition to the risk of the EBUS procedure itself. The investigators are not performing any additional intervention from the usual standard of care for any patient presenting for the EBUS procedure. Essentially the investigators are simply grouping the suction and no suction pathology samples as A and B for pathologic comparison. RESULTS: Among the 26 participants, one of the patients (3.8%) had no adequate tissue using both methods; one patient (3.8%) had adequate tissue using suction but no adequate tissue using no suction; and 24 patients had adequate tissue using both methods (92.3%, p= 1.00). Among the twenty-four patients with adequate tissue using both methods, 14 patients (58.3%) had benign pathology using both methods, while ten patients (41.7%) had malignant pathology using both methods (p= 1.00). Considering suction to be the golden method, the sensitivity and specificity of no suction were 100%. Among the 32 sites that were sampled, one site (3.1%) had no adequate tissue using both methods; one site (3.1%) had adequate tissue using suction but no adequate tissue using no suction; and 30 sites had adequate tissue using both methods (93.8%, p= 1.00). Among the thirty sites with adequate tissue using both methods, 17 (56.7%) had benign pathology using both methods; 12 (40.0%) had malignant pathology using both methods; and one site (3.3%) had malignant pathology using suction, but benign pathology using no suction (p= 1.00). Considering suction to be the golden method, the no suction had a sensitivity= 92.3% and specificity= 100%.
Age
18 - No limit years
Sex
ALL
Healthy Volunteers
No
Staten Island University Hospital
Staten Island, New York, United States
Start Date
February 1, 2011
Primary Completion Date
November 1, 2011
Completion Date
November 1, 2011
Last Updated
November 28, 2012
30
ACTUAL participants
Endobronchial Ultrasound
PROCEDURE
Lead Sponsor
Northwell Health
NCT07301411
NCT05374447
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT07424807