Randomized Clinical Evaluation of LeGoo™ Internal Vessel Occluder Vs Traditional Vessel Loops
The primary purpose of this study is to demonstrate the clinical safety and efficacy of LeGoo™ in comparison to a standard vessel occlusion method (i.e. vessel loops). Although LeGoo™ is suitable for use in any vascular surgery where temporary vessel occlusion is desired, this study specifically focuses on the use of LeGoo™ in off-pump coronary bypass (OPCAB), as a most sensitive model of adverse changes that may occur at any vascular site.
The purpose of this study is to evaluate the clinical efficacy of LeGoo™ as compared to a traditional vessel loop. LeGoo is a device that is intended to be used during surgical procedures to temporarily occlude blood vessels while forming an anastomosis. LeGoo™ will be evaluated in subjects undergoing off-pump coronary artery by-pass (OPCAB) surgery. This is a prospective, randomized trial with a 30-day follow-up period. Half of the eligible patients will be randomized to the experimental group (LeGoo™); and the other half to the control group (standard vessel loops). LeGoo™ is polymer-based device which is comprised of a non-toxic and biocompatible gel that exists as a liquid at low temperatures and rapidly transitions to a solid at body temperature, forming a plug that can occlude blood vessels. LeGoo™ is injected into a blood vessel that is intended to be occluded, where it stays in a "plug" form for several minutes allowing the surgeon to work in a bloodless field. The gel dissolves with time (spontaneously) or can be reversed back to liquid instantly by cooling the site with ice or irrigating with cold saline. Once dissolved below a minimum concentration, the polymer can never re-solidify. The primary research hypothesis is that surgeons will obtain a bloodless surgical field and achieve satisfactory hemostasis in a larger proportion of anastomoses using LeGoo™ than using a conventional temporary hemostasis technique. Satisfactory hemostasis is defined by the surgeon who will quantitate his/her observation about the quality of the surgical field using the following scoring system: 1. \- Excellent hemostasis (no bleeding) 2. \- Minimal bleeding (bleeding does not interfere with suturing) 3. \- Modest bleeding (required intermittent use of another device to control bleeding at the site of the anastomosis) 4. \- Copious bleeding (required continuous use of another device) "Excellent hemostasis" and "minimal bleeding" are considered "satisfactory hemostasis." Satisfactory hemostasis will constitute a treatment success for the purpose of evaluating the primary efficacy of LeGoo. The primary endpoint is the proportion of anastomoses in which satisfactory hemostasis is achieved.
Age
18 - 79 years
Sex
ALL
Healthy Volunteers
No
Klinik fur Herzchirurgie Herzzentrum Leipzig
Leipzig, Germany
Start Date
September 1, 2008
Primary Completion Date
March 1, 2010
Completion Date
March 1, 2010
Last Updated
September 28, 2009
110
ESTIMATED participants
LeGoo
DEVICE
Control
DEVICE
Lead Sponsor
Pluromed, Inc.
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and Conditions