Loading clinical trials...
Loading clinical trials...
Effects of Ultrasound Guidance on the Minimum Effective Anesthetic Volume Required for Interscalene Brachial Plexus Block Versus Nerve Stimulator Guidance
Interscalene brachial plexus block (ISBPB) is a common nerve block given to patients who are undergoing shoulder surgery. This block has a low, but still significant, rate of complications. Reducing the volume of local anesthetic given during the block may allow some of these complications to be avoided. Participants will be randomly assigned to a group to undergo ISBPB under ultrasound or nerve stimulator guidance. Each group will initially receive 10mL of local anesthetic. The volume used for each subsequent patient depends upon the success or failure of the previous patient's block - a failure will cause the volume given to increase by 2.5mL, while a success will cause the volume to decrease by the same amount. We hypothesize that the minimum effective anesthetic volume in 50% of patients will be significantly lower in the ultrasound guided group than in the nerve stimulator group. We further hypothesize that this lower volume will lead to a decreased rate of complications.
This will be a randomized, single-blind, up-down sequential allocation study. Patients will be randomly assigned to one of two groups, and receive either an ultrasound-guided or nerve-stimulator guided interscalene brachial plexus block. The initial local anesthetic volume in both groups will be 10mL. The outcome of each patient's block will determine the dose for the subsequent patient. When an effective ISBPB is observed, as defined by a NRS (patient-rated pain on a scale from 0 to 10) rating of 0 within 30 minutes post-surgery, the volume of local anesthetic solution used for the next patient will be decreased by 2.5mL. Conversely, when an ineffective ISBPB is observed, the volume of local anesthetic used for the next patient will be increased by 2.5mL. The goal of this study is to determine the minimum effective anesthetic volume of ropivacaine 0.5% providing analgesia in patients when using either ultrasound or a nerve stimulator to guide placement of the block. The primary outcome measure will be the pain score of the patient on a numeric rating score during the 30 minutes after surgery. A number of previous studies have suggested that ultrasound-guidance is beneficial for peripheral nerve blocks in terms of block performance time, success rates, and block quality. Some studies have also shown that ultrasound-guidance can reduce the volume of local anesthetic needed to perform a successful block. This study may reveal that less local anesthetic is needed under ultrasound guidance than under nerve stimulator, which may potentially reduce some of the common complications of ISBPB. We hypothesize that ISBPB done under ultrasound guidance will have a lower minimum effective local anesthetic volume than ISBPB done under nerve stimulation. Further, we hypothesize that the lower volume will reduce the incidence of some of the complications of ISBPB. Using lower volumes of local anesthetic while still maintaining effective analgesia may reduce some of the common complications of ISBPB. It may also allow this beneficial analgesic technique to be given to patients with some respiratory risk factors who are currently unable to receive it.
Age
18 - 80 years
Sex
ALL
Healthy Volunteers
No
Sunnybrook Health Sciences Centre
Toronto, Ontario, Canada
Start Date
August 1, 2008
Primary Completion Date
February 1, 2009
Completion Date
July 1, 2009
Last Updated
August 8, 2008
80
ESTIMATED participants
Ultrasound Minimum Effective Anesthetic Volume
OTHER
Nerve Stimulator Minimum Effective Anesthetic Volume
OTHER
Lead Sponsor
Sunnybrook Health Sciences Centre
NCT06826846
NCT07046325
Data Source & Attribution
This clinical trial information is sourced from ClinicalTrials.gov, a service of the U.S. National Institutes of Health.
Modifications: This data has been reformatted for display purposes. Eligibility criteria have been parsed into inclusion/exclusion sections. Location data has been geocoded to enable distance-based search. For the authoritative and most current information, please visit ClinicalTrials.gov.
Neither the United States Government nor Clareo Health make any warranties regarding the data. Check ClinicalTrials.gov frequently for updates.
View ClinicalTrials.gov Terms and ConditionsNCT04669639